Hubbell Aar Add-A-Relay Wiring Diagram
E-1 www.hubbell-wiring.com Wiring Device-Kellems
®
Index
Product Page
Sensor Technology
Technologies for Smart Buildings .................................. E-2
Energy Savings with Occupancy Sensors ........................... E-3
Wall Switches
Wall Switches with Adaptive Technology. . . . . . . . . . . . . . . . . . . . . . . . . . . . E-5
Wall Switches with Passive Infrared Technology and Digital Timer ....... E-6
Ceiling Sensors
Low Voltage and Line Voltage Ceiling Sensors ....................... E-7
Wall Mount Sensors, Control Units and Accessories .................. E-8
OPTIMYZER™ High Bay Controls and Daylight Harvesting ............ E-9
H-MOSS® | MAXX™ Harsh Environment Occupancy Sensors
Watertight OPTIMYZER® ....................................... E-11
WL-Series Wireless Sensors and Controls
Wall Switches with Adaptive Technology. . . . . . . . . . . . . . . . . . . . . . . . . . . E-12
Plug Load Control Products for ASHRAE and CEC Title 24 Compliance
System Overview / Methods for Complaince ....................... E-14
Control Units .................................................E-15
Coverage Patterns, Specifications and Wiring Schematics
WL-Series Wireless Sensors ....................................E-16
Wall Switches ................................................ E-19
Ceiling Sensors ............................................... E-22
OPTIMYZER™ High Bay Controls ................................E-23
H-MOSS® | MAXX™ Harsh Environment Occupancy Sensors .......... E-24
Control Units and Add-A-Relay .................................. E-25
WLC Load Control with Wireless Receive .......................... E-26
Ceiling and Wall Mount Sensors ................................. E-27
WL-Series Wireless Sensors
and Controls
H-MOSS® | MAXX™ Sensors
Wall and Ceiling Mount
Sensors
Section E
H-MOSS® Controls
High Bay and
Daylight Harvesting
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
www.hubbell-wiring.com E-2 Wiring Device-Kellems
®
H-MOSS® Occupancy Sensors Combine Innovative
Technologies for Industry Proven Performance.
H-MOSS® Controls
Technologies for Smart Buildings
How to Select the Right Technology for the Proper Application
Dual technology occupancy sensors
combine both passive infrared (PIR)
and ultrasonic (US) technologies
for maximum reliability. Because
US and PIR need to both detect
occupancy to turn lighting on, dual
technology sensors minimize the risk
of lights coming on when the space
is unoccupied—false triggering.
Continued detection by only one
technology then keeps lighting on as
necessary. Dual technology sensors
offer the best performance for most
applications.
Dual Technology
Ultrasonic (US) technology senses
occupancy by bouncing sound waves (32
kHz - 45 kHz) off of objects and detecting
a frequency shift between the emitted
and reflected sound waves. Movement
by a person or object within a space
causes a shift in frequency, which the
sensor interprets as occupancy. While US
occupancy sensors have a limited range,
they are excellent at detecting even minor
motion such as typing and filing, and they
do not require an unobstructed line-of-
sight. This makes US technology sensors
ideal for an application like an office with
cubicles or a restroom with stalls.
Ultrasonic (US)
Passive infrared (PIR) technology
senses occupancy by detecting the
movement of heat emitted from the
human body against the background
space. Unlike US technology, PIR
sensors require an unobstructed
line-of-sight for detection. These
sensors use a segmented lens, which
divides the coverage area into zones.
Movement between zones is then
interpreted as occupancy. PIR sensors
are ideal for detecting major motion
(e.g. walking), and they work best in
small, enclosed spaces with high levels
of occupant movement.
Passive Infrared (PIR)
Adaptive Technology
Adaptive Technology is a Hubbell breakthrough that
delivers benefits to both building owners and occupants.
The building owner achieves reduced energy costs, fewer
adjustments and less maintenance, and the building
occupant experiences fewer false-offs and disturbances.
Adaptive technology occupancy sensors use
microprocessors that make all the decisions for setting
adjustments. Internal software constantly monitors the
controlled area and automatically adjusts the sensitivity
and timer based on environmental history. This means
that instead of manually adjusting the sensor for seasonal
changes, modified airflow, furniture layout or occupancy
pattern changes, the sensor automatically adjusts itself.
These automatic adjustments eliminate the need for
multiple manual adjustments by maintenance personnel
or outside contractors. Hubbell offers adaptive technology
throughout its product offering—wall switches, ceiling and
wall mount sensors—in conjunction with dual technology,
ultrasonic and passive infrared products.
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
E-3 www.hubbell-wiring.com Wiring Device-Kellems
®
H-MOSS® Controls
Energy Savings with Occupancy Sensors
Hubbell Occupancy Sensors Play a Key Role
In the U.S., lighting consumes 22% of electricity and represents
$40 billion a year in energy costs. Using advanced technology,
Hubbell's H-MOSS® Occupancy Sensors are doing their part
to save energy and provide sustainability by automatically and
effectively turning lights on when a room is occupied and off
when a room is vacant. In a typical office building, where lighting
accounts for 35 to 45% of energy use, H-MOSS Occupancy
Sensors have the potential to reduce wasted lighting by 13% to
90% for a significant return on investment (ROI).
Hubbell offers a broad range of occupancy and vacancy sensors
and lighting controls that meet the latest codes and standards,
including ASHRAE/IESNA 90.1 and California Energy Commission
(CEC) Title 24. H-MOSS Occupancy Sensors can also provide
LEED® points in categories like Sustainable Sites, Energy and
Atmosphere, Indoor Environmental Quality and Innovative
Design Process.
Backed by Hubbell Service and Support
H-MOSS® Occupancy Sensors are backed by Hubbell's GreenWise™
sustainability initiative and superior service and support including:
• Valuable online H-MOSS ROI worksheet for calculating energy savings
• Detailed H-MOSS online e-learning courses that can be taken
anywhere, anytime
• Product selection guide for choosing the right H-MOSS Occupancy
Sensor and technology
• Online specification assistance through spec wizard, AutoCAD
drawings, templates, BIM objects and documentation
• Comprehensive design assistance for deploying occupancy sensors in
a variety of applications
• Highly knowledgeable network of specification professionals and
trained, dedicated sales staff
• Backed by Hubbell who is committed to safeguarding the
environment through environmental stewardship, innovative
products and efficient operations
Electrical bill impact for a typical
ofce building*
Typical Applications
Applications are generalized. Consult
your Hubbell representative for the
type of technology and products
that fit your needs.
Wall Switch Ceiling
Sensor
Wall
Sensor
Application Sensor Technology Sensor Style
Adaptive Dual Ultrasonic PIR Wall Switch Ceiling Wall
Office Small + + +
Large + + +
Open Office + + +
Storage/
Warehouse
Small + +
Large + + + +
Rest Room Small + + +
Large + + +
Conference
Room
Small + + +
Large + + +
Classroom Small + + +
Large + + +
Hall + + +
Potential
electricity
bill savings**
Lighting Uses 39% of Total Electricity
Climate
Control
Lighting
Savings
Refrigeration
Other
27%
5%
15%
14%
39%
16%
Ofce Equipment
Note: *Energy Information Administration:
- Commercial Buildings
- Energy Consumption Survey
**Based on 40% lighting savings from sensors. Actual results may vary.
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
www.hubbell-wiring.com E-4 Wiring Device-Kellems
®
Adaptive Passive Infrared Wall Switches
Features and Benefits
H-MOSS® Controls
Adaptive Dual Technology Wall Switches
Features and Benefits
Available in ivory, white,
black, gray and light almond
Impact resistant hard lens is
standard and color matched
to the switch
Dual technology sensing combines
the individual advantages of passive
infrared and ultrasonic detection
Designed for use on 120 or
277V AC circuits. No neutral
needed for fast retrots
Built in photocell with manual super
saver mode for daylight harvesting
Auto or manual "On" operating
modes. Available in either single
relay or dual relay versions for
enhanced savings with bi-level
switching applications
Adaptive technology - "Install
and forget" operation, analyzes
environment and adjusts sensitivity
and timer, eliminating the need for
manual adjustment
AD2000W1
with NP26W
Wall plate included for simplied
ordering
High density 1200 square foot
180° coverage with tough
tamper resistant lens
Photocell can prevent lights
from turning on with sufcient
natural light
Front press switch allows the
occupant to switch the sensor
from automatic operation to
momentary off mode
Designed for use on 120 or
277V AC circuits. No neutral
needed for fast retrots
Heavy-duty relay controls up to
1000 watts at 120V AC or
1800 watts at 277V AC
Nightlight version available to
provide minimum illumination
when the lights are off
Tamper resistant push button
covers the time-out, service switch,
and vac/occ operation mode
settings
ATP2000W
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
E-5 www.hubbell-wiring.com Wiring Device-Kellems
®
H-MOSS® Controls
Wall Switches
Featuring Adaptive Technology
AD2000W1
AD2000W1N
AD2000W2N
AU2000W1
AU2000W2
AP2000W1
AP2000W2
• Adaptive technology - "Install and forget" operation
• All digital sensing technology
• Dual 120/277V AC operation. No neutral required
• Auto or manual "On" operating modes
• No minimum load requirements
• Hard lens (dual technology, passive infrared)
• Steel mounting strap
• Zero arc point switching
• Built in photocell with manual super saver
mode for daylight harvesting
• Bi-level switching or dual load control
(2 or 2N suffix)
• cULus
Adaptive Technology
Dual (Ultrasonic and Passive Infrared)
1000 square foot coverage with photocell, 800W Incandescent, 1000W Fluorescent at 120V AC,
1800W Fluorescent at 277V AC, 50/60Hz.
Single Circuit Dual Circuit
Description Color
1 button for
manual/auto
control
Auto control
with no button
2 buttons for
manual/auto
control
Auto control
with no button
Dual (ultrasonic and
passive infrared)
Black
Gray
Ivory
Light Almond
White
AD2000BK1
AD2000GY1
AD2000I1
AD2000LA1
AD2000W1
AD2000BK1N
AD2000GY1N
AD2000I1N
AD2000LA1N
AD2000W1N
AD2000BK2
AD2000GY2
AD2000I2
AD2000LA2
AD2000W2
AD2000BK2N
AD2000GY2N
AD2000I2N
AD2000LA2N
AD2000W2N
Note: Wallplate sold separately. Neutral wire versions available. Use ADN prefix when ordering.
See pages E-16 and E-17 for coverage patterns and technical specifications.
Ultrasonic
400 square foot coverage with photocell, 800W Incandescent, 1000W Fluorescent at 120V AC,
1800W Fluorescent at 277V AC, 50/60Hz.
Single Circuit Dual Circuit
Description Color
1 button for
manual/auto
control
Auto control
with no button
2 buttons for
manual/auto
control
Auto control
with no button
Ultrasonic Black
Gray
Ivory
Light Almond
White
AU2000BK1
AU2000GY1
AU2000I1
AU2000LA1
AU2000W1
AU2000BK1N
AU2000GY1N
AU2000I1N
AU2000LA1N
AU2000W1N
AU2000BK2
AU2000GY2
AU2000I2
AU2000LA2
AU2000W2
AU2000BK2N
AU2000GY2N
AU2000I2N
AU2000LA2N
AU2000W2N
Note: Wallplate sold separately. Neutral wire versions available. Use AUN prefix when ordering.
See pages E-16 and E-17 for coverage patterns and technical specifications.
Passive Infrared
1000 sq. ft. coverage with photocell, 800W Incandescent, 1000W Fluorescent at 120V AC,
1800W Fluorescent at 277V AC, 50/60Hz.
Single Circuit Dual Circuit
Description Color
1 button for
manual/auto
control
Auto control
with no button
2 buttons for
manual/auto
control
Auto control
with no button
Passive infrared Black
Gray
Ivory
Light Almond
White
AP2000BK1
AP2000GY1
AP2000I1
AP2000LA1
AP2000W1
AP2000BK1N
AP2000GY1N
AP2000I1N
AP2000LA1N
AP2000W1N
AP2000BK2
AP2000GY2
AP2000I2
AP2000LA2
AP2000W2
AP2000BK2N
AP2000GY2N
AP2000I2N
AP2000LA2N
AP2000W2N
Note: Wallplate sold separately. Neutral wire versions available. Use APN prefix when ordering.
See pages E-16 and E-17 for coverage patterns and technical specifications.
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
www.hubbell-wiring.com E-6 Wiring Device-Kellems
®
H-MOSS® Controls
Wall Switches and Digital Timer
Featuring Passive Infrared Technology
AT1277W
ATP2000W
WS2000W
WS1000W
Digital Timer Wall Switch
Description Color Catalog Number
Dip switch enabled preset intervals, user adjustable up to 4 hours,
3-way capable, 960W @ 120V AC and 1200W @ 277V AC.
Includes an on/off momentary push button switch feature
White DT2000W
Count Down Timer Wall Switch
Description Color
30 Minutes:
Off, 5, 10, 20, 30
60 Minutes:
Off, 15, 30, 45, 60
12 Hours:
Off, 2, 4, 8, 12
1000W @ 120V AC and
1400W @ 277V AC
Ivory
Light Almond
White
DT5030I
DT5030LA
DT5030W
DT5060I
DT5060LA
DT5060W
DT5012I
DT5012LA
DT5012W
DT2000W
DT5030W
Passive Infrared Wall Switches
• Passive infrared technology
• Manual adjustment time delay (20 sec. to 30 min.)
• Photocell (WS2000 series)
• No neutral required
• 1200 sq. ft. coverage
• Wallplate included
• Steel mounting strap
• cULus
Description Color Standard w/ Nightlight w/ Neutral
w/ Nightlight
and Neutral
Manual adjusting; selectable
manual/auto-on operation;
dual-voltage 120/277V;
3-way capable
Gray
Ivory
Light Almond
White
WS2000GY
WS2000I
WS2000LA
WS2000W
WS2000NGY
WS2000NI
WS2000NLA
WS2000NW
—
WS2004I
—
WS2004W
—
WS2004NI
—
WS2004NW
Manual adjusting;
auto-on operation;
120V AC only
Ivory
White
WS1000I
WS1000W
WS1000NI
WS1000NW
—
—
—
—
Manual adjusting;
Manual-on operation;
120V AC only
Ivory
White
WS1001I
WS1001W
WS1001NI
WS1001NW
—
—
—
—
Note: See pages E-17 and E-18 for coverage patterns and technical specifications.
Adaptive Technology, Passive Infrared
• Adaptive technology - "Install and forget" operation
• Passive infrared technology
• Dual 120/277V AC operation, no neutral required
• Heavy duty relay (AT1277xx)
• Audible alarm before turning lights off (AT1277xx)
• 1200 sq. ft. coverage
• Built in photocell for daylight harvesting
• Wallplate included
• Steel mounting strap
• cULus
Description Color Standard w/ Nightlight w/ Neutral
w/ Nightlight
and Neutral
High load adaptive wall
switch, 1800W @ 120V AC
and 4166W @ 277V AC
Ivory
White
AT1277I
AT1277W
—
—
—
—
—
—
Adaptive auto-adjusting;
selectable manual/auto-
on operation; dual-voltage
120/277V; 3-way capable
Gray
Ivory
Light Almond
White
ATP2000GY
ATP2000I
ATP2000LA
ATP2000W
ATP2000NGY
ATP2000NI
ATP2000NLA
ATP2000NW
—
ATP2004I
—
ATP2004W
—
ATP2004NI
—
ATP2004NW
Note: See pages E-17 and E-18 for coverage patterns and technical specifications.
Ceiling Accessories Wall Accessories
Description Catalog Number Description Catalog Number
Ceiling sensor infrared
NEMA 4X enclosure
ACIPE Wall switch wire guard AWSG
Ceiling mount wire guard ACMG Wall mount wire guard AWMG
Ceiling mount raceway adapter ACMRA
AWSG AWMG
ACMG
ACIPE
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
E-7 www.hubbell-wiring.com Wiring Device-Kellems
®
Dual (Ultrasonic and Passive Infrared)
Combines the excellent minor motion detection of ultrasonic with the outstanding passive infrared
(PIR) long-range major motion detection.
Description Coverage Color Catalog Number
Low voltage sensor with photocell and isolated relay
Low voltage sensor
Line voltage sensor
2000 sq. ft. (360°)
2000 sq. ft. (360°)
2000 sq. ft. (360°)
White
White
White
ATD2000CRP
ATD2000C
ATD2000CL
Low voltage sensor with photocell and isolated relay
Low voltage sensor
Line voltage sensor
1000 sq. ft. (180°)
1000 sq. ft. (180°)
1000 sq. ft. (180°)
White
White
White
ATD1000CRP
ATD1000C
ATD1000CL
Low voltage sensor with photocell and isolated relay
Low voltage sensor
500 sq. ft. (180°)
500 sq. ft. (180°)
White
White
ATD500CRP
ATD500C
Note: Low voltage ATD ceiling sensors must use a CU series control units. See page E-8 for details.
See pages E-19 and E-20 for coverage patterns and technical specifications.
Ultrasonic
Excellent minor motion detection.
Description Coverage Color Catalog Number
Low voltage sensor with photocell and isolated relay
Low voltage sensor
Line voltage sensor
2000 sq. ft. (360°)
2000 sq. ft. (360°)
2000 sq. ft. (360°)
White
White
White
ATU2000CRP
ATU2000C
ATU2000CL
Low voltage sensor with photocell and isolated relay
Low voltage sensor
Line voltage sensor
1000 sq. ft. (180°)
1000 sq. ft. (180°)
1000 sq. ft. (180°)
White
White
White
ATU1000CRP
ATU1000C
ATU1000CL
Low voltage sensor with photocell and isolated relay
Low voltage sensor
500 sq. ft. (180°)
500 sq. ft. (180°)
White
White
ATU500CRP
ATU500C
Note: Low voltage ATU ceiling sensors must use a CU series control units. See page E-8 for details.
See pages E-19 and E-20 for coverage patterns and technical specifications.
ATD2000C
Series
ATD1000C/
ATD500C
Series
ATU2000C
Series
ATU1000C/
ATU500C
Series
ATP1500C/
ATP600C
Series
Passive Infrared
Outstanding long range major motion detection.
Description Coverage Color Catalog Number
Low voltage sensor with photocell and isolated relay
Low voltage sensor
Line voltage sensor
1500 sq. ft. (360°)
1500 sq. ft. (360°)
1500 sq. ft. (360°)
White
White
White
ATP1500CRP
ATP1500C
ATP1500CL
Low voltage sensor with photocell and isolated relay
Low voltage sensor
Line voltage sensor
450 sq. ft. (360°)
450 sq. ft. (360°)
450 sq. ft. (360°)
White
White
White
ATP600CRP
ATP600C
ATP600CL
Note: Low voltage ATP ceiling sensors must use a CU series control units. See page E-8 for details.
See pages E-19 and E-20 for coverage patterns and technical specifications.
H-MOSS® Controls
Ceiling Sensors
Featuring Adaptive Technology
Adaptive Technology
• Adaptive technology - "Install and forget"
• All digital sensing technology
• Photocell for daylight harvesting and relay to
interface with auxiliary systems such as
HVAC (CRP models)
• Mounting base included with sensor
• Non-volatile memory settings retained
after power outage
• Low voltage units: 24V DC, 33mA
• Line voltage units: 20A, 120-277V
• 32kHz (ATD/ATU500C and CRP - 40kHz)
• cULus
LVPR1500R
Low Profile, Line Voltage Passive Infrared (PIR)
Outstanding long range major motion detection in a compact low profile housing.
Voltage Coverage Load Rating Color Catalog Number
120-347V AC
with photocell
and isolated relay
1500 sq. ft. 800W Inc. 1000W Fl. @ 120V AC
1800W Fl. @ 277V AC
2200W Fl. @ 347V AC
White LVPR1500R
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
www.hubbell-wiring.com E-8 Wiring Device-Kellems
®
H-MOSS® Controls
Wall Mount Sensors
Line Voltage and Low Voltage
Accessories
Control Units
The CU300 series provides 24V DC power supply for sensors or sensor/Add-A-Relay combinations
The control units contain an internal relay for the control of an external lighting load. Control units are
plenum rated cULus Listed.
Description Catalog Number
Automatic-on operation, 120/277V AC, 50/60Hz for use with 1 to 4 ATD, ATU and ATP series
ceiling/wall mount sensors
CU300A
Manual-on operation, 120/277V AC, 50/60Hz for use with 1 to 4 ATD, ATU and ATP series
ceiling/wall mount sensors
CU300M
Auto or manual-on operation, 120/277V AC, 50/60Hz for use with 1 to 6 ATD, ATU and
ATP series ceiling/wall mount sensors, heavy duty latching relay for reactive loads and
plug-load control
CU300HD
Automatic-on operation, 347V AC, 60Hz, for use with 1 to 3 ATD, ATU and ATP series
ceiling and wall mount sensors
CU347A
Note: See page E-25 for technical specifications.
Add-A-Relay
Hubbell AAR Add-A-Relay contains an internal relay for control of an external lighting load. The AAR
requires a 24V DC power supply from the Hubbell CU series control unit. The AAR is typically used
when: 1. It is desired to switch more than one circuit when occupancy is sensed. 2. The lighting load
exceeds the maximum rating of the control unit.
Description Catalog Number
For use with CU series control units and Hubbell ATD, ATU and ATP series ceiling
and wall mount sensors
AAR
Adaptive Technology Wall Mount Sensors
• Adaptive technology - "Install and forget" operation
• Swivel mounting bracket included for wall or
ceiling mounting
• All digital sensing technology
• Photocell for daylight harvesting and relay
interface with auxiliary systems such as
HVAC (RP models)
• 24V DC, 33mA
• cULus
CU300A(M),
CU347A
AAR
ATD1600W
Series
ATP1600W,
ATP120HB
Series
Dual (Ultrasonic and Passive Infrared)
Description Coverage Color Catalog Number
Low voltage sensor 32kHz with photocell and isolated relay
Low voltage sensor 32kHz
1600 sq. ft.
1600 sq. ft.
White
White
ATD1600WRP
ATD1600W
Passive Infrared
Description Coverage Color Catalog Number
Low voltage sensor with photocell and isolated relay 1600 sq. ft.
1600 sq. ft.
White
White
ATP1600WRP
ATP1600W
Low voltage sensor for aisle and high bay applications,
with photocell and isolated relay
120 linear ft. White ATP120HBRP
Low voltage sensor for aisle and high bay applications 120 linear ft. White ATP120HB
Note: All wall mount sensors must use a CU series control units. See below for details.
See pages E-19 and E-20 for coverage patterns and technical specifications.
DSL30W1
Low Voltage Switches
• Attractive, architectural design
• Available latching or momentary contact
• Mounts to standard single gang box
• 2-year warranty
Description Color Catalog Number
Low voltage switch, latching, 1 button Ivory
White
DSL30I1
DSL30W1
Low voltage switch, momentary, 1 button Ivory
White
DSM30I1
DSM30W1
Low voltage switch, momentary, 2 button Ivory
White
DSM30I2
DSM30W2
Note: Wallplate sold separately.
CU300HD
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
E-9 www.hubbell-wiring.com Wiring Device-Kellems
®
Daylight Harvesting
• Multiple calibration options
• Selectable 3- or 8-second dimming rate
• Low-profile design
• Light-sensitivity range of 0–500 foot candles
Description Voltage Catalog Number
Single zone continuous automatic dimming control
Indoor photocell
Outdoor photocell
Atrium photocell
Skylight photocell
Control module
Daylight tracker with on/off control
Daylight tracker with dimming control
10V DC
24V DC
24V DC
24V DC
24V DC
24V DC
24V DC
24V DC
DHADC†
DHIP
DHOP
DHAP
DHSP
DHCM
DHT*
DHTD†
Note: *For use with CU series control units. See page E-10 for details.
†For use with 0-10V DC dimming ballasts.
For use with DHCM and CU series control units.
HMHB21U
HMHBSA
H-MOSS® Controls
OPTIMYZER® High Bay Controls and Daylight Harvesting
OPTIMYZER® High Bay Controls
• Digital passive infrared (PIR) sensor
• Multiple (single and dual) output versions
• Single and dual timer operation
• Low-profile design
• Supports mounting heights up to 40 ft
• Area and aisle coverage
• Universal voltage (120/277/347V AC) models available
• No minimum load
Standard
Description Voltage Catalog Number
Fluorescent high bay PIR sensor, 1 relay 120-347V AC HMHB21U
Fluorescent high bay PIR sensor, 2 relays 120-347V AC HMHB22U
Fluorescent high bay PIR sensor, 1 double pole relay 208/240V AC HMHB23A
Fluorescent high bay PIR sensor, 1 double pole relay 480V AC HMHB23B
Fluorescent high bay PIR sensor 24V DC HMHB2LV*
Daylight Harvesting (With Photocells)
Description Voltage Catalog Number
Fluorescent high bay PIR sensor, 1 relay with photocell 120-347V AC HMHB21UP
Fluorescent high bay PIR sensor, 2 relays with photocell 120-347V AC HMHB22UP
Fluorescent high bay PIR sensor, 1 double pole relay with photocell 208/240V AC HMHB23AP
Fluorescent high bay PIR sensor, 1 double pole relay with photocell 480V AC HMHB23BP
Fluorescent high bay PIR sensor with photocell 24V DC HMHB2LVP*
See pages E-20 for coverage patterns and technical specifications.
OPTIMYZER® Accessories
Description Catalog Number
High bay mounting extension adapter HMHBSA
External daylight control HMHBEP
Multi-Level Relays
Description Catalog Number
Enclosed independent control for multiple ballast light xtures from one existing wall switch,
bi-level; 120/208-277V AC
AARBL2
Enclosed independent control for multiple ballast light xtures from one existing wall switch,
tri-level; 120/208-277V AC
AARBL3 AARBL2
AAR10C277
Enclosed 10 Amp SPDT Relays
Description Catalog Number
Enclosed relay 10 Amp SPDT with 10-30V AC/DC/120V AC coil AAR10C120
Enclosed relay 10 Amp SPDT with 10-30V AC/DC/208-277V AC coil AAR10C277
DHCM
DHT
DHADC
DHAP, DHSP
DHIP, DHOP
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
www.hubbell-wiring.com E-10 Wiring Device-Kellems
®
H-MOSS® Controls
H-MOSS®|MAXX™ Harsh Environment Occupancy Sensors
Features and Benefits
H-MOSS® |MAXX™ products provide users with methods to reduce energy usage in harsh environments. These applications
often have lights being left on and ventilation/HVAC systems constantly working. H-MOSS® |MAXX™ products are designed
to withstand these challenging environments and provide increased operating efciency.
Fixture or work box mounting
with ½" threaded nipple
Digital passive infrared
(PIR) sensor
Supplied with 360º lens; aisle,
end-of-aisle and 180º lenses
available separately
½" threaded nipple
(HAP4)
Multiple mounting kits for
existing work boxes and hubs;
pendent or wall mounting
exibility
Integrated lens guard protects
against accidental damage
Housing manufactured from
chemical resistant Valox®
IP65, NEMA 3R watertight,
and outdoor rated
Two photocells for daylight
harvesting
IP66, NEMA 4X,
outdoor rated
Photocell makes sure
lights stay off when there
is sufcient daylight
Isolated relay provides
signalling to HVAC and
ventalation systems
Stainless steel hardware
and settings access cover
HMHB21UPCW
AHP1600WRP
with HAP4
Valox ® is a trademark of SABIC Innovative Plastics, acquired from General Electric Company.
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
E-11 www.hubbell-wiring.com Wiring Device-Kellems
®
H-MOSS® Controls
H-MOSS®|MAXX™ Harsh Environment Occupancy Sensors
Ordering Information
Watertight OPTIMYZER®
IP65, NEMA 3R, outdoor rated, -40°F to 149°F (-40°C to 65°C) operating temperature range.
Description Voltage Catalog Number
Pir sensor, relay with photocell 120-347V AC HMHB21UPCW
Pir sensor, 2 relays with photocell 120-347V AC HMHB22UPCW
Pir sensor, 1 double pole relay with photocell 208, 240V AC HMHB23APCW
Pir sensor, 1 double pole relay with photocell 480V AC HMHB23BPCW
Pir sensor, with photocell 24V DC HMHB2LVPCW*
180° Lens — HMHBL180
360° Lens (included) —HMHBL360
Aisle lens —HMHBLA
End of aisle lens — HMHBLEA
Note: *For use with a CU series control unit: CU300HD (120/277V AC, 50/60 Hz), CU347A (347V AC, 60 Hz).
See pages E-21 for coverage patterns and technical specifications.
Outdoor Rated Watertight Wall Mount PIR Sensor
IP66, NEMA 4X, heavy duty wall or pendant mount sensor with -40°F to 149°F (-40°C to 65°C) operating
temperature range and 160° of coverage.
Description Voltage Catalog Number
PIR sensor, with isolated relay and photocell 24V DC AHP1600WRP
Adaptor plate for 1-gang FS boxes — HAP1
Adaptor hub and nipple for Killark NJ series boxes — HAP2
Adaptor plate for Killark NV series boxes — HAP3
½" NPT threaded hub — HAP4
Note: For use with a CU series control unit: CU300HD (120/277V AC, 50/60 Hz), CU347A (347V AC, 60 Hz).
See pages E-21 for coverage patterns and technical specifications.
Extreme Temperature PIR Ceiling Sensor
Upgraded ceiling sensor with -40°F to 149°F (-40°C to 65°C) operating temperature range.
Use ACIPE to make NEMA 4X watertight.
Description Voltage Catalog Number
PIR sensor, with isolated relay and photocell 24V DC AHP1500CRP
IP66, NEMA 4X enclosure — ACIPE
Note: For use with a CU series control unit: CU300HD (120/277V AC, 50/60 Hz), CU347A (347V AC, 60 Hz).
See pages E-21 for coverage patterns and technical specifications.
Heavy Duty Control Unit
Robust latching relay provides reliable performance over many different applications, including plug
loads. 20A 100-277V AC, 1HP @ 120V, 2HP @ 240/277V. Auto or Manual-On operation. Powers up to
six low voltage sensors.
Description Voltage Catalog Number
Heavy duty control unit 120-277V AC CU300HD
Note: See page E-25 for technical specifications. CU300HD
AHP1600WRP
ACIPE with
AHP1500CRP
HMHB21UPCW
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
www.hubbell-wiring.com E-12 Wiring Device-Kellems
®
Three operation modes available:
Auto-On, Auto-On Low-Light
and Manual-On
Passive infrared motion detection
with advanced digital signal
processing for ne motion
detection
Auto-On Low-Light feature will
only turn lights on automatically
if there is less than approximately
10 Lux (1 fc) of ambient light
10-year battery life design
8A lighting, 3A fan
load capacity
Green LED provides
operation and setup
feedback
No neutral required,
no leakage to ground
LED and CFL compatible
with supplied load adaptor
Digital push button
operation provides user
control
Service switch prevents
lights from coming on
during re-lamping
Lens illuminates during
test mode to verify
coverage
Adjustments available
for Timeout, Activity,
and Auto-On settings
Accessible test buttons
make setup easy
WLS1278W
with NP26W
H-MOSS® Controls
WL-Series Wireless Sensors and Controls
Features and Benefits
WLP450C
Clear Connect™ is a registered trademark of Lutron Electronics Co., Inc.
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
E-13 www.hubbell-wiring.com Wiring Device-Kellems
®
H-MOSS® Controls
WL-Series Wireless Sensors and Controls
Featuring Passive Infrared Technology
Clear Connect™ is a registered trademark of Lutron Electronics Co., Inc.
Wireless
Daylight Sensor
Wireless Wall
Mount Sensor
Wireless
Wall Switches
Wireless Ceiling and Wall
Mount Sensors
Hubbell's WL-Series Wireless Sensors and Controls are the ideal solution for renovation projects aimed at reducing energy
consumption. These sensors use DSP Enhanced passive infrared technology to detect movement of heat from people to turn
lights on when a room is occupied and off when vacant. The sensors wirelessly transmit Clear Connect™ commands to the
associated control devices, reducing the need for additional wiring for ease and speed of installation and energy savings.
• Eliminates need to run extra wires
• Supports highly recongured spaces
• Complete projects quickly
• Helps manage energy consumption
Wireless Ceiling Mount Sensor
Description Color Catalog Number
Ceiling mount 360° / 324-676 ft2 White WLP450C
Wireless Wall Mount Sensor
• Detection at longer distances is best when motion occurs at right angles to the sensor
• Multiple sensors can be used to extend coverage
• Mount Hallway Sensor at the end of a hallway with a clear view down the length of a hall
Description
Wall mount
180° / 3000 ft2
Corner mount
90° / 2500 ft2
Hallway
up to 150 linear ft
Color White White White
Catalog Number WLP3000W WLP2500W WLP150H
Compatible Controls: WSL1278xx switch, WLC316R control unit, or any Lutron Clear Connect enabled control device.
Wireless Daylight Sensor
Description Color Catalog Number
Daylight sensor 0–107,000 Lux (0-10,000 fc) White WLDH
Compatible Controls: WSL1278xx switch, WLC316R control unit, or any Lutron Clear Connect enabled control device.
Note: See pages E-22 to E-24 for coverage patterns and technical specifications.
Wireless Wall Switches
Description Color Catalog Number
8A Lighting, 3A Fan (1/10 HP motor, 120V only), Spec Grade
Electronic Switch 120–277V. No neutral wire required
Ivory
White
WLS1278I
WLS1278W
Accessory Switch 120V Ivory
White
WLAS120I
WLAS120W
Accessory Switch 277V Ivory
White
WLAS277I
WLAS277W
Compatible Transmitters: WLP series and WLDH sensors any Lutron Clear Connect enabled sensor.
Wireless Control Unit
Description Catalog Number
Wireless load control unit with isolated relay, 16A, 120V or 277V AC WLC316R
Compatible Transmitters: WLP series and WLDH sensors any Lutron Clear Connect enabled sensor.
WLP450C
WLP150H
WLS1278I WLAS277W
WLC316R
WLDH
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
www.hubbell-wiring.com E-14 Wiring Device-Kellems
®
H-MOSS® Controls
Plug Load Control Products for ASHRAE and CEC Title 24 Compliance
System Overview / Methods for Complaince
ASHRAE 90.1-2010 mandates that 50% of all outlets in private ofces, open ofces, and
computer classrooms must be automatically controlled by occupancy or time based schedules.
This also includes outlets in modular furniture. Hubbell provides solutions for compliance that are
cost effective and installer friendly. Bellow are two examples. Additional examples and design
resources are located at www.hubbell-wiring.com/energy.aspx
Wired
Utilizing low voltage wiring provides installers with a familiar method of wiring and installation.
Specify CU300HD to control outlets and use AAR or CU300A to control the lighting. Utilize
alternating outlet or split receptacle wiring as required to control at least 50% of the outlets
in the space.
Wireless
Wireless communication takes complexity out of retrot and difcult installations by eliminating low
voltage wires running between lighting and receptacle control units. This gives installers exibility
to quickly deploy, add additional devices, and congure and re-congure the system as needed.
Hubbell's WL series controls utilize Lutron's proven Clear Connect™ communication and are
compatible with other Clear Connect™ devices, such as Hubbell's wireless occupancy sensors.
CU300xx
CU300HD
Controlling 50%
of Outlets
X
Not used
WLCU301
WLC301
Controlling 50%
of Outlets
DR20LA
Shown with adhesive label
to denote the device is being
automatically controlled.
Labels provided with each
plug load control unit.
Clear Connect™ is a registered trademark of Lutron Electronics Co., Inc.
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
E-15 www.hubbell-wiring.com Wiring Device-Kellems
®
H-MOSS® Controls
Plug Load Control Products for ASHRAE and CEC Title 24 Compliance
Control Units
Hubbell Plug Load Control Products
• Wired or wireless exibility
• UL/cUL 916 listed for energy management equipment
• Listed for 20A enclosed switching
• Heavy duty 60A rated mechanical latching relay;
silver alloy contacts
• Zero cross switching
• Expanded operating temperature range
• 24V DC, 250mA DC power output on applicable units
• Low voltage output short circuit protection
• UL2043 plenum rated except WLC402
• Controlled outlet labels provided with control units
Heavy Duty Control Unit
Robust latching relay provides reliable performance over many different applications, including plug
loads. 20A 100-277V AC, 1HP @ 120V, 2HP @ 240/277V. Auto or manual-on operation. Power up to
six low voltage sensors.
Description Voltage Catalog Number
Heavy duty control unit 100-277V AC CU300HD
Note: See page E-25 for technical specifications.
Heavy Duty Control Unit with Wireless Transmit
CU300HD with functionality of WLCA integrated to wirelessly activate additional load control units.
Takes the place of CU300A's normally used to control just lighting. 20A 100-277V AC, 1HP @ 120V,
2HP @ 240/277V. Auto or manual-on operation. Power up to six low voltage sensors.
Description Voltage Catalog Number
Heavy duty control unit with Clear Connect 100-277V AC WLCU301
Wireless Status Transmitter
Low voltage powered unit transmits occupancy or timer status to associated load control receivers.
Use with CU300xx and low voltage sensors/timers to upgrade existing lighting control systems to
support plug load control.
Description Voltage Catalog Number
Wireless transmitter with Clear Connect, for use with CU300xx 24V DC WLCA
Heavy Duty Load Control Units with Wireless Receive
These units receive wireless Clear Connect ™ commands to turn on and off power to downstream loads.
Utilize these control units to wirelessly switch a circuit of receptacles or any other applicable load.
20A 100-277V AC, 1HP @ 120V, 2HP @ 240/277V.
Description Voltage Catalog Number
1 - Circuit heavy duty control unit with Clear Connect 100-277V AC WLC301
2 - Circuit heavy duty control unit with Clear Connect 100-277V AC WLC302
Furniture Feed Box with Heavy Duty Relays and Wireless Receive
Furniture feed box receives wireless Clear Connect ™ commands and controls 2-circuits in furniture
electrical feeds. It supports wall mounting to existing 1 or 2-gang junction boxes. Additionally, the box
can be secured to the furniture or on the floor. 20A 100-277V AC, 1HP @ 120V, 2HP @ 240/277V.
Description Voltage Catalog Number
2 - Circuit heavy duty furniture freed box with
Clear Connect
100-277V AC WLC402W
Note: See page E-26 for technical specifications.
WLCU301
WLC301
CU300HD
WLCA
WLC402W
Clear Connect™ is a registered trademark of Lutron Electronics Co., Inc.
Wired
Wireless
Operates in a "quiet" 434MHz FCC band. Communication range: 30 ft obstructed or 60 ft
line of sight
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
www.hubbell-wiring.com E-16 Wiring Device-Kellems
®
Load 1
Red
Black
120/277V AC
Green
Ground
Red
Violet
Black
Blue
Line circuit
120/277V AC
Green
Ground
Load 1
Load 2
Red
Violet
Black
Blue
Line circuit 1
120/277V AC
Line circuit 2
120/277V AC
Green
Ground
Load 1
Load 2
Neutral
Hot
Ground
Black Red
Green
Neutral
Hot
Ground
Black
Red
Green
Violet
Blue
Lighting
Load A Lighting
Load A
Lighting
Load B
Wiring Schematic AD, AU, AP, 1277/2000 Series Wall Switch Sensors
H-MOSS® Controls
Specifications and Wiring Schematics
Dual Technology and Ultrasonic Wall Switches
Adaptive Dual Technology Wall Switches
AD2000 Series
Electrical
Power Supply 120/277V AC, 50/60Hz
Load Capacity
Incandescent 0 to 800 watts
120V AC Ballast 0 to 1000 watts
277V AC Ballast 0 to 1800 watts
Agency Approvals cULus Listed
Physical
Housing High impact plastic (UL-94-5V)
Lens Dual element pyrometer and 12 element
cylindrical hard lens
Dimensions Face 2.59"H x 1.73"W, 0.37"D (from wall out)
Mounting Height 42 to 54 inches above floor
Environmental
Operating 32°F to 104°F (0°C to 40°C);
0% to 95% non-condensing relative humidity
Controls
Time Delay Digital, adaptive 4 to 30 minutes
Ambient Light Adjustable ambient light override, 10 to 500
foot candles
Front Press Switch Auto/Off
Sensitivity Adaptive 0% to 100%
Service Switch Air gap off
Sensing Indicator
Passive Infrared Red LED
Ultrasonic Green LED
Adaptive Technology Ultrasonic and PIR Wall Switches
AP2000 and AU2000 Series
Electrical
Power Supply 120/277V AC, 50/60Hz
Load Capacity
Incandescent 0 to 800 watts
120V AC Ballast 0 to 1000 watts
277V AC Ballast 0 to 1800 watts
Agency Approvals cULus Listed
Physical
Housing High impact plastic (UL-94-5V)
Lens Dual element pyrometer and 12 element
cylindrical hard lens (AP2000 only)
Dimensions Face 2.59"H x 1.73"W, 0.37"D (from wall out)
Mounting Height 42 to 54 inches above floor
Environmental
Operating 32° F to 104°F (0°C to 40°C);
0% to 95% non-condensing relative humidity
Controls
Time Delay Digital, adaptive 4 to 30 minutes
20 minutes default
Ambient Light Adjustable ambient light override, 10 to 500
foot candles
Front Press Switch Auto/Off
Sensitivity Adaptive 0% to 100%
Service Switch Air gap off
Sensing Indicator
Passive Infrared Red LED (AP series only)
Ultrasonic Green LED (AU series only)
Single Circuit Wiring Dual Circuit Sensor, Wired for Dual Circuits Dual Circuit Sensor, Wired for Single Circuit
Single Circuit Sensors, Wired as 3-Way Sensors* Dual Circuit Sensors, Wired as 3-Way Sensors*
Note: *Load can not exceed the rating of one switch.
Sensor is shipped with all dip switches in the OFF position (factory default).
For step dimming,
bi-level, and dual
ballasted xtures
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
E-17 www.hubbell-wiring.com Wiring Device-Kellems
®
Wall Switches Coverage Patterns
Major Motion: UltrasonicUltrasonic PIRPIR
Minor Motion:
AD2000 Series
28'
28'
24'
29'
26'
21'
50'
AP2000 Series
28'
28'
50'
AU2000 Series
14.5'
14.5'
24'
26'
21'
16'
16'
40'
AT1277 Series
3.5º
3.5º
10'
(3.0m)
Mounting Height
42" to 54"
(106.7 to 137.2cm)
20'
(6.1m)
See Horizontal
View for Range
14.5"
(36.8cm)
29"
(73.3cm)
Vertical Coverage
AT1277 Series
Wall Switches Coverage Patterns
Major Motion: PIRPIR
Minor Motion:
H-MOSS® Controls
Coverage Patterns
ATP2000, WS2000 Series
12'
16'
12'
16'
40'
20'
Mounting Height
48" (121.9 cm)
20' (6.1m)
40' (12.2m)
Vertical Coverage
ATP2000, WS2000 Series
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
www.hubbell-wiring.com E-18 Wiring Device-Kellems
®
Adaptive Technology PIR Wall Switches
AT1277 Series
Electrical AT1277 Series
Power Supply 120/277V AC, 50/60Hz
Load Capacity
120V AC 0 to 1800 watts
277V AC 0 to 4155 watts
Agency Approvals UL Listed, cULus Certified
Physical
Housing Flame retardant UL 94 V-0 ABS
Lens Polyethylene
Dimensions Face 2.61"H x 1.29"W, 0.73"D (from wall out)
Mounting Height 42 to 54 inches above floor
Environmental
Operating 32°F to 122°F (0°C to 50°C) with rate of
change not exceeding 20°F
(11°C) per hour; 20% to 90% non-condensing
relative humidity
Storage -20°F to 150°F (-29°C to 65°C);
20% to 90% non condensing relative humidity
Controls
Time Delay Digital, test (15 seconds),
Adaptive 5 to 30 minutes
Ambient Light Digital, pushbutton, 30 to 300 foot candles
Front Press Switch Auto/Momentary Off (30 minutes after last
motion, switch returns to automatic mode)
Service Switch Auto/Off
Sensing Indicators
Passive Infrared 2-color LED (red, green)
Note: *Load can not exceed the rating of one switch.
H-MOSS® Controls
Specifications and Wiring Schematics
Passive Infrared Wall Switches
Hot
Hot
Ground
Ground
Green
Green Green
Yellow
Neutral Neutral
Red
Normal Wiring
Sensors Wired as
3-Way Sensors*
(ATP/WS2000 Only)
White (Neutral Versions Only)
Black White
Black
Red Red
Yellow
White (Neutral
Version Only) Load Load
ATP/WS2000
Only
Adaptive Technology PIR Wall Switches
ATP2000, WS2000 and WS1000 Series
Electrical ATP/WS2000 Series WS1000 Series
Power Supply 120/277V AC, 60Hz 120V AC, 60Hz
Load Capacity
Incandescent 0 to 1000 watts 0 to 500 watts
120V Ballast 0 to 1000 watts 0 to 500 watts
277V Ballast 0 to 1800 watts N/A
Agency Approvals
Warranty
cULus Listed
5 years
cULus Listed
5 years
Physical ATP/WS2000 and WS1000 Series
Housing Flame retardant UL 94 V-0 ABS
Lens Polyethylene
Dimensions Face 2.59"H x 1.30"W, 0.61"D (from wall out)
Mounting Height 42 to 54 inches above floor
Environmental ATP/WS2000 and WS1000 Series
Operating 32°F to 122°F (0°C to 50°C) with rate of change
not exceeding 20°F (11°C) per hour; 20% to 90%
non-condensing relative humidity
Storage -40°F to 150°F (-40°C to 65°C);
20% to 90% non condensing relative humidity
Controls ATP/WS2000 Series WS1000 Series
Time Delay ATP: Auto
WS: Manual 20 seconds
to 30 minutes
Manual 20 seconds to
30 minutes
Ambient Light Digital, pushbutton,
10 to 500 foot candles
n/a
Front Press Switch On/Off On/Off
Service Switch Off (service)
Vac (manual-on)
Occ (auto-on)
Off (service)
On (normal operation)
Sensing Indicator ATP/WS2000 and WS1000 Series
Passive Infrared Red LED
Wiring Schematic ATP2000 and WS2000 Series Wall Switches
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
E-19 www.hubbell-wiring.com Wiring Device-Kellems
®
32'
64'
45'
23'
23'
32'
32'
23'
ATU2000C Series ATU1000C Series
26'
18'
14'
20'
ATU500C Series
64'
16'
ATU2000C Series
Hallway Application
ATD2000C Series ATD1000C Series ATD500C Series ATP1500C Series ATP600C Series
22'
26' 18'
12'
14'
20'
22'
64'
45'
12'
23'
32'
22'
32'
23'
12'
23'
32'
22' 12'
11'
7'
Ceiling Sensors Coverage Patterns
Major Motion: UltrasonicUltrasonic PIRPIR
Minor Motion:
LVPR1500R(P)
20'
Wall Mount Sensors Coverage Patterns
20
10
0
30
120'
7'
7'
120'
ATP120HB Series
Top View
Side View
40'
20'
32'
23'
32'
23'
ATD1600W Series
40'
20'
ATP1600W Series
Major Motion: UltrasonicUltrasonic PIRPIR
Minor Motion:
H-MOSS® Controls
Coverage Patterns
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
www.hubbell-wiring.com E-20 Wiring Device-Kellems
®
H-MOSS® Controls
Specifications
Ceiling and Wall Mount Sensors
Adaptive Dual Technology, Ultrasonic and Passive Infrared Ceiling and Wall Mount Sensors
ATD, ATU, and ATP Series
Electrical
Power Requirements 24V DC nominal, 33mA from Hubbell CU series control unit
Isolated Relay Normally open and normally closed
(sensors with RP suffix) Terminals available
Agency Approvals UL Listed
Physical Ceiling Sensors
Housing Flame retardant UL 94 V-0 ABS
Lens Polyethylene
Dimensions 1.5"H x 4.5"D
Color Office white
Mounting Height 8 to 12 feet
Physical Wall Mount Sensors
Housing Flame retardant UL 94 V-0 ABS
Lens Polyethylene
Dimensions 6"H x 2"W x 1.5"D
Color Office white
Mounting Height 8 to 12 feet, 8 to 30 feet (ATP120HB series)
Environmental
Operating 32°F to 104°F (0°C to 40°C) with rate of change not exceeding 20°F (11°C) per hour;
0% to 95% non condensing relative humidity
Storage -20°F to 150°F (-29°C to 65°C); 0% to 95% non-condensing relative humidity
Controls
Time Delay Test (8 seconds), adaptive 8 to 40 minutes
Ambient Light 1 to 1000 foot candles
Sensitivity Adaptive 0 to 100%
Sensing Indicators
Ultrasonic (ATD and ATU Series) Green LED
Passive Infrared (ATD and ATP Series) Red LED
OPTIMYZER® High Bay
HMHB Series
User Interface 2 four-pin dip switches (standard version)
3 four-pin dip switches (photosensor version)
Timer time-outs Primary: 8-second test mode – 4, 8, 16 and 30 minute time-outs
Secondary: Can be disabled – 30, 60 and 90 minute time-outs
Passive infrared Dual element pyrometer and spherical Fresnel lens
Photosensor Range
(Photosensor version only)
50 to 3000 foot candles, set point adjustable
Coverage 360° (includes masking kit for aisle and end-of-aisle applications).
Lens: Below 30 ft: 1.4 – 42 ft radius; mounted @ 30 ft; up to 45 ft: 1.1 -
49.5 ft radius; mounted @ 45 ft
Load ratings
(line voltage units)
120V AC: 0 to 800
watts watts
277V AC: 0 to 1200 watts ballast
347V AC: 0 to 1500 watts ballast
208/240V AC: 0 to 1200 watts ballast
480V AC: 0 to 2400 watts ballast
¼-HP motor load @ 120V AC,
1/6 HP @ 347V
Operating environment
(
Indoor use only)
Operating temperature: (standard version) 32°F to 149°F (0°C to 65°C);
Relative humidity (non-condensing): 0% to 95%
Construction Casing: High-impact injection-molded thermoplastic
Size and weight Size: 4.4 inch x 3.6 inch x 2.0 inch; Weight: 7 oz.
Color White
Mounting Mounts directly to the end of a xture through an extended ½ inch chase
nipple. For deeper body xtures, an optional Extender Adapter (available
separately) positions the sensor ush or below the bottom of the reector
for a full eld of view
Certications cULus Listed
R
1
H
= 0' to 30'
R
2
R
1
= 1.4 x H
R
2
= 1.1 x H
H
= 30' to 45'
Coverage Pattern
Major Motion: PIRPIR
Minor Motion:
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
E-21 www.hubbell-wiring.com Wiring Device-Kellems
®
R
1
H
= 0' to 30'
R
2
R
1
= 1.4 x H
R
2
= 1.1 x H
H
= 30' to 45'
Coverage Pattern
Major Motion: PIRPIR
Minor Motion:
H-MOSS® Controls
Specifications
Ceiling and Wall Mount Sensors
Harsh Environment Passive Infrared Ceiling and Wall Mount Sensors
AHP Series
Electrical
Power Requirements 24V DC nominal, 33mA from Hubbell CU series control unit
Isolated Relay Normally open and normally closed
(sensors with RP suffix) Terminals available
Agency Approvals cULus Listed
Physical Ceiling Sensor
Housing Flame retardant UL 94 V-0 ABS
Protection NEMA 4X, when used with ACIPE
Lens Polyethylene
Dimensions 1.5"H x 4.5"D
Color Office white
Mounting Height 8 to 12 feet
Physical Wall Mount Sensor
Housing Flame retardant UL 94 V-0 Valox®
Protection NEMA 4X, IP66, outdoor use rated
Lens Polyethylene
Dimensions 6"H x 2"W x 1.5"D
Color Gray
Mounting Height 8 to 12 feet
Environmental
Operating -40°F to 149°F (-40°C to 65°C) with rate of change
not exceeding 20°F (11°C) per hour;
0% to 95% non condensing relative humidity
Controls
Time Delay Test (8 seconds), adaptive 8 to 40 minutes
Ambient Light 1 to 1000 foot candles
Sensitivity Adaptive 0 to 100%
Sensing Indicators
Passive Infrared Red LED
HMHBxxUPCW Series
User Interface 2 four-pin dip switches (standard version)
3 four-pin dip switches (photosensor version)
Timer time-outs Primary: 8-second test mode 4, 8, 16 and 30 minute time-outs
Secondary: Can be disabled 30, 60 and 90 minute time-outs
Passive infrared Dual element pyrometer and spherical Fresnel lens
Photosensor Range
(Photosensor version only)
50 to 3000 foot candles, set point adjustable
Coverage 360° (includes masking kit for aisle and end-of-aisle applications)
Lens: Below 30 ft: 1.4 – 42 ft radius; mounted @ 30 ft.; Up to 45 ft.:
1.1 - 49.5 ft. radius; mounted @ 45 ft.
Load ratings
(line voltage units)
120V AC: 0 to 800 watts ballast or tungsten
277V AC: 0 to 1200 watts ballast
347V AC: 0 to 1500 watts ballast
208/240V AC: 0 to 1200 watts ballast
480V AC: 0 to 2400 watts ballast
¼-HP motor load @ 120V AC, 1/6 HP @ 347V
Operating environment
(Indoor use only)
Operating temperature: (standard version) 32°F to 149°F (0°C to
65°C); (low temperature version): -40°F to 149°F (-40°C to 65°C)
Relative humidity (non-condensing): 0% to 95%
Construction Casing: High-impact injection-molded thermoplastic
Size and weight Size: 4.4 inch x 3.6 inch x 2.0 inch; Weight: 7 oz.
Color White
Mounting Mounts directly to the end of a xture through an extended ½ inch
chase nipple. For deeper body xtures, an optional Extender
Adapter (available separately) positions the sensor ush or below
the bottom of the reector for a full eld of view
Certications ETL, Conforms to UL STD 916, Certied to CAN/USA STD 22.2
No. 61010-1-04 and Title 24 Certied
Warranty 5 year limited
AHP1500CRP
22'
26' 18'
12'
14'
20'
22'
64'
45'
12'
23'
32'
22'
32'
23'
12'
23'
32'
22' 12'
40'
20'
AHP1600WRP
Coverage Pattern
Major Motion: PIRPIR
Minor Motion:
Valox ® is a trademark of SABIC Innovative Plastics, acquired from General Electric Company.
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
www.hubbell-wiring.com E-22 Wiring Device-Kellems
®
Wireless Ceiling Mount Sensor Coverage Patterns
Sensor Coverage Chart (for sensor mounted in center of room)
Ceiling height Maximum room dimensions for complete oor coverage*
8 ft (2.4 m) 18 ft x 18 ft (5.5 m × 5.5 m) 324 ft 2 (30.2 m 2)
9 ft (2.7 m) 20 ft x 20 ft (6.1 m × 6.1 m) 400 ft 2 ( 37. 2 m 2 )
10 ft (3.0 m) 22 ft x 22 ft (6.7 m × 6.7 m) 484 ft 2 (44.9 m 2 )
12 ft (3.7 m) 26 ft x 26 ft (7.9 m × 7.9 m 676 ft 2 (62.4 m 2 )
Note: * 12 ft (3.7 m) is the recommended maximum mounting height
11'
7'
8'
6'
12'
Wireless Wall Mount Sensor Coverage Patterns Corner Mount Coverage Patterns
H-MOSS® Controls
Coverage Patterns
WL-Series Wireless Sensors
Note: *Sensor mounting shown at 7 ft (2.1 m). Mounting height should be between 6 and 8 ft (1.6 and 2.4 m).
Side View
WLP450C
60'
50'
25'
18'
25'
18'
0'
0
750'
60'
Side View
Top View
WLP3000W
0
7
35'
50'
Side View
35'
50'
Top View
WLP2500W
Clear Connect™ is a registered trademark of Lutron Electronics Co., Inc.
Top View
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
E-23 www.hubbell-wiring.com Wiring Device-Kellems
®
Specications
Electrical Operating voltage: 3V
Operating current: 14 μA nominal
10-year battery life design
Supplied with one CR 123 lithium battery
Non-volatile memory (saved changes are stored during power loss)
Construction High impact, UL 94-5V plastic
Operating Environment Indoor use only
Operating temperature: 32˚F to 104˚F (0˚C to 40˚C)
Range RF range is 30 ft (10m) obstructed, 60 ft (18m) line of sight
Sensor Coverage Test Dedicated test button
Lens illuminates orange in response to motion during test mode
Wireless Communication Test Dedicated test button; Turn associated loads on and off
Time Out Options 1 minute (intended for use in high-activity, briey occupied areas only); 5 minutes;
15 minutes (default setting); 30 minutes
Auto-On Options "Enabled" – Sensor turns lights ON and OFF automatically – default setting
"Disabled" – Lights must be turned ON manually from a switching device
Sensor turns lights OFF automatically
Sensitivity Options Low Activity (default setting); Medium Activity; High Activity
Certications cULus Listed, FCC Certied, IC Certied
Meets CA (USA) Energy Commission Title 24 requirements
Warranty 1 year
Wireless Hallway Sensor Coverage Patterns
10'
150'
7'
150'
0
Side View
Top View
Sensor Coverage Chart (Hallway)
Width of Hall Length of Hall
6 ft (1.0 m) or less 50 ft (15.2 m)
8 ft (2.4 m) 100 ft (30.5 m)
10 ft (3.0 m) or more 150 ft (45.7 m)
Note: *Sensor mounting shown at 7 ft (2.1 m). Mounting height
should be between 6 and 8 ft (1.6 and 2.4 m).
H-MOSS® Controls
Coverage Patterns
WL-Series Wireless Sensors
WPL150H
Clear Connect™ is a registered trademark of Lutron Electronics Co., Inc.
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
www.hubbell-wiring.com E-24 Wiring Device-Kellems
®
H-MOSS® Controls
Specifications and Wiring Schematics
WL-Series Wireless Load Controls
Wireless Control Unit (WLC316R)
Electrical Operating voltage: 120/277V, 50/60Hz
LED status indicator: displays load status and provides programming feedback
Power failure memory: (Relay returns to previous level prior to interruption)
Output is non-latching
Operating
Environment
Indoor use only
Ambient operating temperature: 32°F to 131°F (0°C to 55°C);
Relative humidity: 0% to 90% humidity, non-condensing
Load Maximum load: 16A general purpose. No minimum
Motor rating: 0.5 HP (120V AC), 1.5 HP (277V AC)
Isolated Relay Normally open (NO) and normally closed (NC) dry contacts
Maintained latching output
The isolated relay is not rated to control unclamped, inductive loads.
Inductive loads include, but are not limited to relays, solenoids and motors.
To control these types of equipment
Range RF range is 30 ft (10m) obstructed, 60 ft (18m) line of sight
Certications UL Listed, UL 2043 Plenum Rated, FCC Approved. Complies with the limits
for a Class B device, pursuant to Part 15 of the FCC rules. CSA and IC
Warranty 1 year
Range Diagram
40 ft (12 m)
Install in center of room to
maximize RF coverage.
Wireless Transmitter
must be installed within
30 ft (10 m) of the
load control unit.
Line of sight distance
60 ft (18 m)
Wireless
Occupancy
Sensor
30 ft (10 m)
Maximum
30 ft (10 m)
Contact Hubbell first for applications using foil-backed or metallic ceiling tiles.
Contact Hubbell rst for applications
using foil-backed or metallic ceiling tiles.
Wireless Wall Switch (WLS1278 Series)
Electrical Operating voltage: 120/277V, 50/60Hz
Green indicator light
Operating
Environment
Indoor use only
Ambient operating temperature: 32°F to 104°F (0°C to 40°C),
Relative humidity: 0% to 90% humidity, non-condensing
Wire Size #20 to 16 AWG (0.5 to 1.5mm 2 ) solid or stranded wire
Capacity Up to 9 WLAS accessory switches can be congured to work together with one WLS1278
Range RF range is 30 ft (10m) obstructed, 60 ft (18m) line of sight
Certications UL Listed, CSA Certied, FCC Approved
Complies with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules
Warranty 1 year
Wiring Diagram - Wireless Wall Switch (WLS1278 Series)
Note: *The included LUT-MLC ensures proper function when flfluorescent, CFL,
or LED loads are used. Install the LUT-MLC inside a load fixture or in a
separate J-box of the circuit.
1 When using controls in single location installations, tighten the blue
terminal without any wires attached. DO NOT connect the blue terminal to
any other wiring or to ground.
2 Up to 9 Accessory Switches may be connected to the Wireless Switch.
Total blue terminal wire length may be up to 250 ft (76m).
3 Requires WLAS120 for 120V applications, and WLAS277 for 277V
applications.
Single Location Installation
WLS1278xx*
Brass
Black
Blue - unused, tighten1
Optional
Green
Ground
Hot/Live
Neutral
Switch
Load
120V
50/60 Hz
or
277V
50/60 Hz
LUT-MLC*
WLS1278xx
Switch
Multi-Location Installation2
with WLAS1278xx or WLAS277xx3
Brass
Black
Blue
Green
Ground
Brass
Black
Blue
Green
Ground
Brass
Black
Blue
Green
Ground
Hot/Live
Neutral
WLAS Series
Companion Switch WLAS Series
Companion Switch
Load
120V
50/60 Hz
or
277V
50/60 Hz
Optional
LUT-MLC*
Clear Connect™ is a registered trademark of Lutron Electronics Co., Inc.
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
E-25 www.hubbell-wiring.com Wiring Device-Kellems
®
Control Units - CU300/347A Series
Electrical CU300A(M) CU347A CU300HD
Power Supply 120-277V AC, 50/60Hz 347V AC, 60Hz 100-277V AC, 50/60 Hz
Power Output 24V DC, 150mA 24V DC, 100mA 24V DC 250mA
Load Capacity
Incandescent 0 to 1800 watts NA 100-277V, 20A Enclosed Switching
120V Ballast 0 to 2400 watts NA Motor Loads:
230V Ballast NA NA 1HP @ 120V
277V Ballast 0 to 5540 watts NA 2HP @ 240/277V
347V Ballast NA 0 to 5205 watts
AT Sensor/AAR Capacity 1 to 4 combined 1 to 3 combined 1 to 6 combined
Agency Approvals UL Listed, cULus Certified UL Listed, cULus Certified UL Listed, cULus
Physical
Housing Flame retardant UL 94-5VA thermoplastic Flame retardant UL 94-5VA thermoplastic
Dimensions 3.69"L x 2.33"W x 1.36"H 4.00"L x 3.4"W x 1.73"H
Color Black Black
Environmental
Operating 32°F to 104°F (0°C to 40°C); 0% to 90% non condensing relative humidity See CU300HD data sheet for ratings
Storage -20°F to 150°F (-29°C to 65°C); 0% to 90% non condensing relative humidity
Add-A-Relay - AAR
Electrical
Power Input 24V DC nominal, 33mA from Hubbell CU series control unit
Load Capacity
Incandescent 0 to 1800 watts
120V Ballast 0 to 2400 watts
230V Ballast 0 to 3680 watts
277V Ballast 0 to 5540 watts
347V Ballast 0 to 5205 watts
Agency Approvals UL Listed
Physical
Housing Flame retardant UL 94-5V thermoplastic
Dimensions 3.69"L x 2.33"W x 1.36"H
Color Black
Environmental
Operating 32°F to 104°F (0°C to 40°C); 0% to 90% non condensing relative humidity
Storage -20°F to 150°F (-29°C to 65°C); 0% to 90% non condensing relative humidity
H-MOSS® Controls
Specifications
Control Units and Add-A-Relay
CU300xx
CU300HD
Controlling 50%
of Outlets
X
Not used
Wired Lighting and Plug Load Control
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
www.hubbell-wiring.com E-26 Wiring Device-Kellems
®
H-MOSS® Controls
Specifications and Wiring Schematics
Passive Infrared Wall Switches
WLC Load Control with Wireless Clear Connect Communication
Electrical WLCA WLCU301 WLC301 WLC302 WLC402W
Power Supply 24V DC 100-277V AC, 50/60Hz 100-277V AC, 50/60Hz 100-277V AC, 50/60Hz 100-277V AC, 50/60Hz
Power Output N/A 24V DC 250mA N/A N/A N/A
Circuits Controlled N/A 1122
Load Capacity 100-277V, 20A
1HP @ 120V AC
2HP @ 240/277V
100-277V, 20A
1HP @ 120V AC
2HP @ 240/277V
100-277V, 20A
1HP @ 120V AC
2HP @ 240/277V
100-277V, 20A
1HP @ 120V AC
2HP @ 240/277V
Agency Approvals UL Listed, cULus, FCC, IC
Device Type (Transmit
or Receive)
TX TX RX RX RX
Range (Standard/
Obtructed)
30 ft (10m) 30 ft (10m) 30 ft (10m) 30 ft (10m) 30 ft (10m)
Range (Unobstructed,
line of site)
60 ft (30m) 60 ft (30m) 60 ft (30m) 60 ft (30m) 60 ft (30m)
Physical
Housing Flame retardant UL 94-5VA thermoplastic
Dimensions 4.00"L x 3.4"W x 1.73"H 4.68"L x 4.94"W x 2.78"H
Color Black Black Black Black White
WLCU301
WLC301
Controlling 50%
of Outlets
CU300xx WLCA
WLC301
Controlling 50%
of Outlets
Easily upgrade existing occupancy based lighting control systems to support
automated plug load controls.
Wireless Lighting and Plug Load Control
Use WLC302
or 402 for dual
circuit control)
Clear Connect™ is a registered trademark of Lutron Electronics Co., Inc.
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
E-27 www.hubbell-wiring.com Wiring Device-Kellems
®
White
Black
Red
Red
Lighting Load
Red
Black
Blue
ATD, ATU and ATP Series Sensors**
Blue
Blk
Red
Blue
Blk
Red
Blue
Blk
Red
Switch*
*Optional Override Off Switch
White
Black
Red
Red
Lighting Load
NH
Red
Red
Lighting Load
NH
Red
Black
Blue
Red
Black
Blue
ATD, ATU and ATP Series Sensors**
Blue
Blk
Red
Blue
Blk
Red
AAR Add-A-Relay
White
Black
Red
Red
Lighting Load
Red
Red
Lighting Load
Red (+24V)
Black
Blue
Red (+24V)
Black
Blue
ATD, ATU and ATP Series Sensors**
Blue
Blk
Red
Blue
Blk
Red
Blue
Blk
Red
Blue
Blk
Red
White
White
Black
White
CU Series Control Unit
BlackBlue
CU Series Control Unit
ATD, ATU and ATP Series Sensors**
CU Series Control Unit
(Specify Voltage)
White
Black
Red
Red
Lighting Load
NH
NH
Lighting Load
Red (+24V)
Black
Blue
Red (+24V)
Black
Blue
Blue
Blk
Red
Blue
Blk
Red
Blue
Blk
Red
Blue
Blk
Red
White BlackBlue
White
Black
Red
Red
White
H-MOSS® Controls
Wiring Schematics
Ceiling and Wall Mount Sensors
Adaptive Dual Technology, Ultrasonic, and Passive Infrared Ceiling and Wall Mount Sensors
ATD, ATU and ATP Series
Two Circuit Application:
1 to 4 sensors wired to control unit and Add-A-Relay (control
unit switches circuit 1, Add-A-Relay switches circuit 2).
Note: **For wiring sensors with isolated relay and photocell option (models
with "RP" suffix): Photocell Option: Cap off Blue sensor wire. Connect
Gray sensor wire to Blue control unit wire. Isolated Relay Option:
Common-Blue/White wire, Normally Closed-Black/White wire,
Normally Open-Yellow/White wire.
Two Circuit Application:
Two control units wired in two circuits to operate 2 to 8 sensors
in a single zone. Maximum 4 sensors per control unit any
sensor will activate both lighting loads.
Single Circuit Application:
Two control units wired in parallel to operate 5 to 8 sensors
in a single zone. Maximum 4 sensors per control unit any
sensor will activate lighting.
Single Circuit Application:
1 to 4 sensors wired to control unit with optional override
off switch.
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
www.hubbell-wiring.com E-28 Wiring Device-Kellems
®
CU Series Control Unit
(Specify Voltage)
Red
Blk
Blue
Red
Blk
Blue
Red
Blk
Blue
Red
Black
Blue
Red
Red
Black
White White
Inboard Ballast
Outboard Ballast
ATD, ATU and ATP Series Sensors**
Single Pole Switch
Single Pole Switch
N
H
CU Series Control Unit
(Specify Voltage)
Red
Blk
Blue
Red
Blk
Blue
Red
Blk
Blue
Red
Black
Blue
Red
Red
Black
White White
ATD, ATU and ATP Series Sensors**
Traveler
3-Way Switch 3-Way Switch
Lighting Load
NH
CU Series Control Unit
(Specify Voltage)
Red
Blk
Blue
Red
Blk
Blue
Red
Blk
Blue
Red
Black
Blue
Red
Red
Black
White White
ATD, ATU and ATP Series Sensors**
Traveler
3-Way Switch 4-Way Switch
Lighting Load
3-Way Switch
Traveler
Lighting Contactor
ATD, ATU, ATP, PIR Series Sensors*
White
Black
Red
Red
Red (+24V)
Black
Blue
Blue
Blk
Red
Blue
Blk
Red
White
C
Multipole, Normally Open
Lighting contactor to be
H-MOSS® Controls
Wiring Schematics
Ceiling and Wall Mount Sensors
Adaptive Technology Dual, Ultrasonic, and Passive Infrared Ceiling and Wall Mount Sensors
ATD, ATU and ATP Series
Single Circuit, Dual Level Switching Application:
1 to 4 sensors wired to control unit with optional override
off switches.
Single Circuit, 4-Way Switching Application:
1 to 4 sensors wired to control unit with optional override
off switches.
Single Circuit, 3-Way Switching Application:
1 to 4 sensors wired to control unit with optional override
off switches.
Multi-Circuit Application:
1 to 4 sensors wired to control unit that is wired to a
multi-pole lighting contactor.
Note: **For wiring sensors with isolated relay and photocell option (models
with "RP" suffix): Photocell Option: Cap off Blue sensor wire. Connect
Gray sensor wire to Blue control unit wire. Isolated Relay Option:
Common-Blue/White wire, Normally Closed-Black/White wire,
Normally Open-Yellow/White wire.
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
Source: https://usermanual.wiki/Pdf/104769Catalog.1401849935/html
Posted by: gordonsabor1950aep.blogspot.com