E-1 www.hubbell-wiring.com Wiring Device-Kellems

®

Index

Product Page

Sensor Technology

Technologies for Smart Buildings .................................. E-2

Energy Savings with Occupancy Sensors ........................... E-3

Wall Switches

Wall Switches with Adaptive Technology. . . . . . . . . . . . . . . . . . . . . . . . . . . . E-5

Wall Switches with Passive Infrared Technology and Digital Timer ....... E-6

Ceiling Sensors

Low Voltage and Line Voltage Ceiling Sensors ....................... E-7

Wall Mount Sensors, Control Units and Accessories .................. E-8

OPTIMYZER™ High Bay Controls and Daylight Harvesting ............ E-9

H-MOSS® | MAXX™ Harsh Environment Occupancy Sensors

Watertight OPTIMYZER® ....................................... E-11

WL-Series Wireless Sensors and Controls

Wall Switches with Adaptive Technology. . . . . . . . . . . . . . . . . . . . . . . . . . . E-12

Plug Load Control Products for ASHRAE and CEC Title 24 Compliance

System Overview / Methods for Complaince ....................... E-14

Control Units .................................................E-15

Coverage Patterns, Specifications and Wiring Schematics

WL-Series Wireless Sensors ....................................E-16

Wall Switches ................................................ E-19

Ceiling Sensors ............................................... E-22

OPTIMYZER™ High Bay Controls ................................E-23

H-MOSS® | MAXX™ Harsh Environment Occupancy Sensors .......... E-24

Control Units and Add-A-Relay .................................. E-25

WLC Load Control with Wireless Receive .......................... E-26

Ceiling and Wall Mount Sensors ................................. E-27

WL-Series Wireless Sensors

and Controls

H-MOSS® | MAXX™ Sensors

Wall and Ceiling Mount

Sensors

Section E

H-MOSS® Controls

High Bay and

Daylight Harvesting

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

www.hubbell-wiring.com E-2 Wiring Device-Kellems

®

H-MOSS® Occupancy Sensors Combine Innovative

Technologies for Industry Proven Performance.

H-MOSS® Controls

Technologies for Smart Buildings

How to Select the Right Technology for the Proper Application

Dual technology occupancy sensors

combine both passive infrared (PIR)

and ultrasonic (US) technologies

for maximum reliability. Because

US and PIR need to both detect

occupancy to turn lighting on, dual

technology sensors minimize the risk

of lights coming on when the space

is unoccupiedfalse triggering.

Continued detection by only one

technology then keeps lighting on as

necessary. Dual technology sensors

offer the best performance for most

applications.

Dual Technology

Ultrasonic (US) technology senses

occupancy by bouncing sound waves (32

kHz - 45 kHz) off of objects and detecting

a frequency shift between the emitted

and reflected sound waves. Movement

by a person or object within a space

causes a shift in frequency, which the

sensor interprets as occupancy. While US

occupancy sensors have a limited range,

they are excellent at detecting even minor

motion such as typing and filing, and they

do not require an unobstructed line-of-

sight. This makes US technology sensors

ideal for an application like an office with

cubicles or a restroom with stalls.

Ultrasonic (US)

Passive infrared (PIR) technology

senses occupancy by detecting the

movement of heat emitted from the

human body against the background

space. Unlike US technology, PIR

sensors require an unobstructed

line-of-sight for detection. These

sensors use a segmented lens, which

divides the coverage area into zones.

Movement between zones is then

interpreted as occupancy. PIR sensors

are ideal for detecting major motion

(e.g. walking), and they work best in

small, enclosed spaces with high levels

of occupant movement.

Passive Infrared (PIR)

Adaptive Technology

Adaptive Technology is a Hubbell breakthrough that

delivers benefits to both building owners and occupants.

The building owner achieves reduced energy costs, fewer

adjustments and less maintenance, and the building

occupant experiences fewer false-offs and disturbances.

Adaptive technology occupancy sensors use

microprocessors that make all the decisions for setting

adjustments. Internal software constantly monitors the

controlled area and automatically adjusts the sensitivity

and timer based on environmental history. This means

that instead of manually adjusting the sensor for seasonal

changes, modified airflow, furniture layout or occupancy

pattern changes, the sensor automatically adjusts itself.

These automatic adjustments eliminate the need for

multiple manual adjustments by maintenance personnel

or outside contractors. Hubbell offers adaptive technology

throughout its product offering—wall switches, ceiling and

wall mount sensors—in conjunction with dual technology,

ultrasonic and passive infrared products.

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

E-3 www.hubbell-wiring.com Wiring Device-Kellems

®

H-MOSS® Controls

Energy Savings with Occupancy Sensors

Hubbell Occupancy Sensors Play a Key Role

In the U.S., lighting consumes 22% of electricity and represents

$40 billion a year in energy costs. Using advanced technology,

Hubbell's H-MOSS® Occupancy Sensors are doing their part

to save energy and provide sustainability by automatically and

effectively turning lights on when a room is occupied and off

when a room is vacant. In a typical office building, where lighting

accounts for 35 to 45% of energy use, H-MOSS Occupancy

Sensors have the potential to reduce wasted lighting by 13% to

90% for a significant return on investment (ROI).

Hubbell offers a broad range of occupancy and vacancy sensors

and lighting controls that meet the latest codes and standards,

including ASHRAE/IESNA 90.1 and California Energy Commission

(CEC) Title 24. H-MOSS Occupancy Sensors can also provide

LEED® points in categories like Sustainable Sites, Energy and

Atmosphere, Indoor Environmental Quality and Innovative

Design Process.

Backed by Hubbell Service and Support

H-MOSS® Occupancy Sensors are backed by Hubbell's GreenWise

sustainability initiative and superior service and support including:

Valuable online H-MOSS ROI worksheet for calculating energy savings

Detailed H-MOSS online e-learning courses that can be taken

anywhere, anytime

Product selection guide for choosing the right H-MOSS Occupancy

Sensor and technology

Online specification assistance through spec wizard, AutoCAD

drawings, templates, BIM objects and documentation

Comprehensive design assistance for deploying occupancy sensors in

a variety of applications

Highly knowledgeable network of specification professionals and

trained, dedicated sales staff

Backed by Hubbell who is committed to safeguarding the

environment through environmental stewardship, innovative

products and efficient operations

Electrical bill impact for a typical

ofce building*

Typical Applications

Applications are generalized. Consult

your Hubbell representative for the

type of technology and products

that fit your needs.

Wall Switch Ceiling

Sensor

Wall

Sensor

Application Sensor Technology Sensor Style

Adaptive Dual Ultrasonic PIR Wall Switch Ceiling Wall

Office Small + +  +

Large + +  +

Open Office + + +

Storage/

Warehouse

Small + +

Large + + + +

Rest Room Small + + +

Large + + +

Conference

Room

Small + + +

Large + + +

Classroom Small + + +

Large + + +

Hall + +  +

Potential

electricity

bill savings**

Lighting Uses 39% of Total Electricity

Climate

Control

Lighting

Savings

Refrigeration

Other

27%

5%

15%

14%

39%

16%

Ofce Equipment

Note: *Energy Information Administration:

- Commercial Buildings

- Energy Consumption Survey

**Based on 40% lighting savings from sensors. Actual results may vary.

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

www.hubbell-wiring.com E-4 Wiring Device-Kellems

®

Adaptive Passive Infrared Wall Switches

Features and Benefits

H-MOSS® Controls

Adaptive Dual Technology Wall Switches

Features and Benefits

Available in ivory, white,

black, gray and light almond

Impact resistant hard lens is

standard and color matched

to the switch

Dual technology sensing combines

the individual advantages of passive

infrared and ultrasonic detection

Designed for use on 120 or

277V AC circuits. No neutral

needed for fast retrots

Built in photocell with manual super

saver mode for daylight harvesting

Auto or manual "On" operating

modes. Available in either single

relay or dual relay versions for

enhanced savings with bi-level

switching applications

Adaptive technology - "Install

and forget" operation, analyzes

environment and adjusts sensitivity

and timer, eliminating the need for

manual adjustment

AD2000W1

with NP26W

Wall plate included for simplied

ordering

High density 1200 square foot

180° coverage with tough

tamper resistant lens

Photocell can prevent lights

from turning on with sufcient

natural light

Front press switch allows the

occupant to switch the sensor

from automatic operation to

momentary off mode

Designed for use on 120 or

277V AC circuits. No neutral

needed for fast retrots

Heavy-duty relay controls up to

1000 watts at 120V AC or

1800 watts at 277V AC

Nightlight version available to

provide minimum illumination

when the lights are off

Tamper resistant push button

covers the time-out, service switch,

and vac/occ operation mode

settings

ATP2000W

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

E-5 www.hubbell-wiring.com Wiring Device-Kellems

®

H-MOSS® Controls

Wall Switches

Featuring Adaptive Technology

AD2000W1

AD2000W1N

AD2000W2N

AU2000W1

AU2000W2

AP2000W1

AP2000W2

Adaptive technology - "Install and forget" operation

All digital sensing technology

Dual 120/277V AC operation. No neutral required

Auto or manual "On" operating modes

No minimum load requirements

Hard lens (dual technology, passive infrared)

Steel mounting strap

Zero arc point switching

Built in photocell with manual super saver

mode for daylight harvesting

Bi-level switching or dual load control

(2 or 2N suffix)

• cULus

Adaptive Technology

Dual (Ultrasonic and Passive Infrared)

1000 square foot coverage with photocell, 800W Incandescent, 1000W Fluorescent at 120V AC,

1800W Fluorescent at 277V AC, 50/60Hz.

Single Circuit Dual Circuit

Description Color

1 button for

manual/auto

control

Auto control

with no button

2 buttons for

manual/auto

control

Auto control

with no button

Dual (ultrasonic and

passive infrared)

Black

Gray

Ivory

Light Almond

White

AD2000BK1

AD2000GY1

AD2000I1

AD2000LA1

AD2000W1

AD2000BK1N

AD2000GY1N

AD2000I1N

AD2000LA1N

AD2000W1N

AD2000BK2

AD2000GY2

AD2000I2

AD2000LA2

AD2000W2

AD2000BK2N

AD2000GY2N

AD2000I2N

AD2000LA2N

AD2000W2N

Note: Wallplate sold separately. Neutral wire versions available. Use ADN prefix when ordering.

See pages E-16 and E-17 for coverage patterns and technical specifications.

Ultrasonic

400 square foot coverage with photocell, 800W Incandescent, 1000W Fluorescent at 120V AC,

1800W Fluorescent at 277V AC, 50/60Hz.

Single Circuit Dual Circuit

Description Color

1 button for

manual/auto

control

Auto control

with no button

2 buttons for

manual/auto

control

Auto control

with no button

Ultrasonic Black

Gray

Ivory

Light Almond

White

AU2000BK1

AU2000GY1

AU2000I1

AU2000LA1

AU2000W1

AU2000BK1N

AU2000GY1N

AU2000I1N

AU2000LA1N

AU2000W1N

AU2000BK2

AU2000GY2

AU2000I2

AU2000LA2

AU2000W2

AU2000BK2N

AU2000GY2N

AU2000I2N

AU2000LA2N

AU2000W2N

Note: Wallplate sold separately. Neutral wire versions available. Use AUN prefix when ordering.

See pages E-16 and E-17 for coverage patterns and technical specifications.

Passive Infrared

1000 sq. ft. coverage with photocell, 800W Incandescent, 1000W Fluorescent at 120V AC,

1800W Fluorescent at 277V AC, 50/60Hz.

Single Circuit Dual Circuit

Description Color

1 button for

manual/auto

control

Auto control

with no button

2 buttons for

manual/auto

control

Auto control

with no button

Passive infrared Black

Gray

Ivory

Light Almond

White

AP2000BK1

AP2000GY1

AP2000I1

AP2000LA1

AP2000W1

AP2000BK1N

AP2000GY1N

AP2000I1N

AP2000LA1N

AP2000W1N

AP2000BK2

AP2000GY2

AP2000I2

AP2000LA2

AP2000W2

AP2000BK2N

AP2000GY2N

AP2000I2N

AP2000LA2N

AP2000W2N

Note: Wallplate sold separately. Neutral wire versions available. Use APN prefix when ordering.

See pages E-16 and E-17 for coverage patterns and technical specifications.

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

www.hubbell-wiring.com E-6 Wiring Device-Kellems

®

H-MOSS® Controls

Wall Switches and Digital Timer

Featuring Passive Infrared Technology

AT1277W

ATP2000W

WS2000W

WS1000W

Digital Timer Wall Switch

Description Color Catalog Number

Dip switch enabled preset intervals, user adjustable up to 4 hours,

3-way capable, 960W @ 120V AC and 1200W @ 277V AC.

Includes an on/off momentary push button switch feature

White DT2000W

Count Down Timer Wall Switch

Description Color

30 Minutes:

Off, 5, 10, 20, 30

60 Minutes:

Off, 15, 30, 45, 60

12 Hours:

Off, 2, 4, 8, 12

1000W @ 120V AC and

1400W @ 277V AC

Ivory

Light Almond

White

DT5030I

DT5030LA

DT5030W

DT5060I

DT5060LA

DT5060W

DT5012I

DT5012LA

DT5012W

DT2000W

DT5030W

Passive Infrared Wall Switches

Passive infrared technology

Manual adjustment time delay (20 sec. to 30 min.)

Photocell (WS2000 series)

No neutral required

1200 sq. ft. coverage

Wallplate included

Steel mounting strap

• cULus

Description Color Standard w/ Nightlight w/ Neutral

w/ Nightlight

and Neutral

Manual adjusting; selectable

manual/auto-on operation;

dual-voltage 120/277V;

3-way capable

Gray

Ivory

Light Almond

White

WS2000GY

WS2000I

WS2000LA

WS2000W

WS2000NGY

WS2000NI

WS2000NLA

WS2000NW

WS2004I

WS2004W

WS2004NI

WS2004NW

Manual adjusting;

auto-on operation;

120V AC only

Ivory

White

WS1000I

WS1000W

WS1000NI

WS1000NW

Manual adjusting;

Manual-on operation;

120V AC only

Ivory

White

WS1001I

WS1001W

WS1001NI

WS1001NW

Note: See pages E-17 and E-18 for coverage patterns and technical specifications.

Adaptive Technology, Passive Infrared

Adaptive technology - "Install and forget" operation

Passive infrared technology

Dual 120/277V AC operation, no neutral required

Heavy duty relay (AT1277xx)

Audible alarm before turning lights off (AT1277xx)

1200 sq. ft. coverage

Built in photocell for daylight harvesting

Wallplate included

Steel mounting strap

• cULus

Description Color Standard w/ Nightlight w/ Neutral

w/ Nightlight

and Neutral

High load adaptive wall

switch, 1800W @ 120V AC

and 4166W @ 277V AC

Ivory

White

AT1277I

AT1277W

Adaptive auto-adjusting;

selectable manual/auto-

on operation; dual-voltage

120/277V; 3-way capable

Gray

Ivory

Light Almond

White

ATP2000GY

ATP2000I

ATP2000LA

ATP2000W

ATP2000NGY

ATP2000NI

ATP2000NLA

ATP2000NW

ATP2004I

ATP2004W

ATP2004NI

ATP2004NW

Note: See pages E-17 and E-18 for coverage patterns and technical specifications.

Ceiling Accessories Wall Accessories

Description Catalog Number Description Catalog Number

Ceiling sensor infrared

NEMA 4X enclosure

ACIPE Wall switch wire guard AWSG

Ceiling mount wire guard ACMG Wall mount wire guard AWMG

Ceiling mount raceway adapter ACMRA

AWSG AWMG

ACMG

ACIPE

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

E-7 www.hubbell-wiring.com Wiring Device-Kellems

®

Dual (Ultrasonic and Passive Infrared)

Combines the excellent minor motion detection of ultrasonic with the outstanding passive infrared

(PIR) long-range major motion detection.

Description Coverage Color Catalog Number

Low voltage sensor with photocell and isolated relay

Low voltage sensor

Line voltage sensor

2000 sq. ft. (360°)

2000 sq. ft. (360°)

2000 sq. ft. (360°)

White

White

White

ATD2000CRP

ATD2000C

ATD2000CL

Low voltage sensor with photocell and isolated relay

Low voltage sensor

Line voltage sensor

1000 sq. ft. (180°)

1000 sq. ft. (180°)

1000 sq. ft. (180°)

White

White

White

ATD1000CRP

ATD1000C

ATD1000CL

Low voltage sensor with photocell and isolated relay

Low voltage sensor

500 sq. ft. (180°)

500 sq. ft. (180°)

White

White

ATD500CRP

ATD500C

Note: Low voltage ATD ceiling sensors must use a CU series control units. See page E-8 for details.

See pages E-19 and E-20 for coverage patterns and technical specifications.

Ultrasonic

Excellent minor motion detection.

Description Coverage Color Catalog Number

Low voltage sensor with photocell and isolated relay

Low voltage sensor

Line voltage sensor

2000 sq. ft. (360°)

2000 sq. ft. (360°)

2000 sq. ft. (360°)

White

White

White

ATU2000CRP

ATU2000C

ATU2000CL

Low voltage sensor with photocell and isolated relay

Low voltage sensor

Line voltage sensor

1000 sq. ft. (180°)

1000 sq. ft. (180°)

1000 sq. ft. (180°)

White

White

White

ATU1000CRP

ATU1000C

ATU1000CL

Low voltage sensor with photocell and isolated relay

Low voltage sensor

500 sq. ft. (180°)

500 sq. ft. (180°)

White

White

ATU500CRP

ATU500C

Note: Low voltage ATU ceiling sensors must use a CU series control units. See page E-8 for details.

See pages E-19 and E-20 for coverage patterns and technical specifications.

ATD2000C

Series

ATD1000C/

ATD500C

Series

ATU2000C

Series

ATU1000C/

ATU500C

Series

ATP1500C/

ATP600C

Series

Passive Infrared

Outstanding long range major motion detection.

Description Coverage Color Catalog Number

Low voltage sensor with photocell and isolated relay

Low voltage sensor

Line voltage sensor

1500 sq. ft. (36)

1500 sq. ft. (36)

1500 sq. ft. (36)

White

White

White

ATP1500CRP

ATP1500C

ATP1500CL

Low voltage sensor with photocell and isolated relay

Low voltage sensor

Line voltage sensor

450 sq. ft. (360°)

450 sq. ft. (360°)

450 sq. ft. (360°)

White

White

White

ATP600CRP

ATP600C

ATP600CL

Note: Low voltage ATP ceiling sensors must use a CU series control units. See page E-8 for details.

See pages E-19 and E-20 for coverage patterns and technical specifications.

H-MOSS® Controls

Ceiling Sensors

Featuring Adaptive Technology

Adaptive Technology

Adaptive technology - "Install and forget"

All digital sensing technology

Photocell for daylight harvesting and relay to

interface with auxiliary systems such as

HVAC (CRP models)

Mounting base included with sensor

Non-volatile memory settings retained

after power outage

Low voltage units: 24V DC, 33mA

Line voltage units: 20A, 120-277V

32kHz (ATD/ATU500C and CRP - 40kHz)

• cULus

LVPR1500R

Low Profile, Line Voltage Passive Infrared (PIR)

Outstanding long range major motion detection in a compact low profile housing.

Voltage Coverage Load Rating Color Catalog Number

120-347V AC

with photocell

and isolated relay

1500 sq. ft. 800W Inc. 1000W Fl. @ 120V AC

1800W Fl. @ 277V AC

2200W Fl. @ 347V AC

White LVPR1500R

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

www.hubbell-wiring.com E-8 Wiring Device-Kellems

®

H-MOSS® Controls

Wall Mount Sensors

Line Voltage and Low Voltage

Accessories

Control Units

The CU300 series provides 24V DC power supply for sensors or sensor/Add-A-Relay combinations

The control units contain an internal relay for the control of an external lighting load. Control units are

plenum rated cULus Listed.

Description Catalog Number

Automatic-on operation, 120/277V AC, 50/60Hz for use with 1 to 4 ATD, ATU and ATP series

ceiling/wall mount sensors

CU300A

Manual-on operation, 120/277V AC, 50/60Hz for use with 1 to 4 ATD, ATU and ATP series

ceiling/wall mount sensors

CU300M

Auto or manual-on operation, 120/277V AC, 50/60Hz for use with 1 to 6 ATD, ATU and

ATP series ceiling/wall mount sensors, heavy duty latching relay for reactive loads and

plug-load control

CU300HD

Automatic-on operation, 347V AC, 60Hz, for use with 1 to 3 ATD, ATU and ATP series

ceiling and wall mount sensors

CU347A

Note: See page E-25 for technical specifications.

Add-A-Relay

Hubbell AAR Add-A-Relay contains an internal relay for control of an external lighting load. The AAR

requires a 24V DC power supply from the Hubbell CU series control unit. The AAR is typically used

when: 1. It is desired to switch more than one circuit when occupancy is sensed. 2. The lighting load

exceeds the maximum rating of the control unit.

Description Catalog Number

For use with CU series control units and Hubbell ATD, ATU and ATP series ceiling

and wall mount sensors

AAR

Adaptive Technology Wall Mount Sensors

Adaptive technology - "Install and forget" operation

Swivel mounting bracket included for wall or

ceiling mounting

All digital sensing technology

Photocell for daylight harvesting and relay

interface with auxiliary systems such as

HVAC (RP models)

24V DC, 33mA

• cULus

CU300A(M),

CU347A

AAR

ATD1600W

Series

ATP1600W,

ATP120HB

Series

Dual (Ultrasonic and Passive Infrared)

Description Coverage Color Catalog Number

Low voltage sensor 32kHz with photocell and isolated relay

Low voltage sensor 32kHz

1600 sq. ft.

1600 sq. ft.

White

White

ATD1600WRP

ATD1600W

Passive Infrared

Description Coverage Color Catalog Number

Low voltage sensor with photocell and isolated relay 1600 sq. ft.

1600 sq. ft.

White

White

ATP1600WRP

ATP1600W

Low voltage sensor for aisle and high bay applications,

with photocell and isolated relay

120 linear ft. White ATP120HBRP

Low voltage sensor for aisle and high bay applications 120 linear ft. White ATP120HB

Note: All wall mount sensors must use a CU series control units. See below for details.

See pages E-19 and E-20 for coverage patterns and technical specifications.

DSL30W1

Low Voltage Switches

Attractive, architectural design

Available latching or momentary contact

Mounts to standard single gang box

2-year warranty

Description Color Catalog Number

Low voltage switch, latching, 1 button Ivory

White

DSL30I1

DSL30W1

Low voltage switch, momentary, 1 button Ivory

White

DSM30I1

DSM30W1

Low voltage switch, momentary, 2 button Ivory

White

DSM30I2

DSM30W2

Note: Wallplate sold separately.

CU300HD

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

E-9 www.hubbell-wiring.com Wiring Device-Kellems

®

Daylight Harvesting

Multiple calibration options

Selectable 3- or 8-second dimming rate

Low-profile design

Light-sensitivity range of 0500 foot candles

Description Voltage Catalog Number

Single zone continuous automatic dimming control

Indoor photocell

Outdoor photocell

Atrium photocell

Skylight photocell

Control module

Daylight tracker with on/off control

Daylight tracker with dimming control

10V DC

24V DC

24V DC

24V DC

24V DC

24V DC

24V DC

24V DC

DHADC

DHIP

DHOP

DHAP

DHSP

DHCM

DHT*

DHTD

Note: *For use with CU series control units. See page E-10 for details.

†For use with 0-10V DC dimming ballasts.

For use with DHCM and CU series control units.

HMHB21U

HMHBSA

H-MOSS® Controls

OPTIMYZER® High Bay Controls and Daylight Harvesting

OPTIMYZER® High Bay Controls

Digital passive infrared (PIR) sensor

Multiple (single and dual) output versions

Single and dual timer operation

Low-profile design

Supports mounting heights up to 40 ft

Area and aisle coverage

Universal voltage (120/277/347V AC) models available

No minimum load

Standard

Description Voltage Catalog Number

Fluorescent high bay PIR sensor, 1 relay 120-347V AC HMHB21U

Fluorescent high bay PIR sensor, 2 relays 120-347V AC HMHB22U

Fluorescent high bay PIR sensor, 1 double pole relay 208/240V AC HMHB23A

Fluorescent high bay PIR sensor, 1 double pole relay 480V AC HMHB23B

Fluorescent high bay PIR sensor 24V DC HMHB2LV*

Daylight Harvesting (With Photocells)

Description Voltage Catalog Number

Fluorescent high bay PIR sensor, 1 relay with photocell 120-347V AC HMHB21UP

Fluorescent high bay PIR sensor, 2 relays with photocell 120-347V AC HMHB22UP

Fluorescent high bay PIR sensor, 1 double pole relay with photocell 208/240V AC HMHB23AP

Fluorescent high bay PIR sensor, 1 double pole relay with photocell 480V AC HMHB23BP

Fluorescent high bay PIR sensor with photocell 24V DC HMHB2LVP*

See pages E-20 for coverage patterns and technical specifications.

OPTIMYZER® Accessories

Description Catalog Number

High bay mounting extension adapter HMHBSA

External daylight control HMHBEP

Multi-Level Relays

Description Catalog Number

Enclosed independent control for multiple ballast light xtures from one existing wall switch,

bi-level; 120/208-277V AC

AARBL2

Enclosed independent control for multiple ballast light xtures from one existing wall switch,

tri-level; 120/208-277V AC

AARBL3 AARBL2

AAR10C277

Enclosed 10 Amp SPDT Relays

Description Catalog Number

Enclosed relay 10 Amp SPDT with 10-30V AC/DC/120V AC coil AAR10C120

Enclosed relay 10 Amp SPDT with 10-30V AC/DC/208-277V AC coil AAR10C277

DHCM

DHT

DHADC

DHAP, DHSP

DHIP, DHOP

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

www.hubbell-wiring.com E-10 Wiring Device-Kellems

®

H-MOSS® Controls

H-MOSS®|MAXX™ Harsh Environment Occupancy Sensors

Features and Benefits

H-MOSS® |MAXX™ products provide users with methods to reduce energy usage in harsh environments. These applications

often have lights being left on and ventilation/HVAC systems constantly working. H-MOSS® |MAXX™ products are designed

to withstand these challenging environments and provide increased operating efciency.

Fixture or work box mounting

with ½" threaded nipple

Digital passive infrared

(PIR) sensor

Supplied with 360º lens; aisle,

end-of-aisle and 180º lenses

available separately

½" threaded nipple

(HAP4)

Multiple mounting kits for

existing work boxes and hubs;

pendent or wall mounting

exibility

Integrated lens guard protects

against accidental damage

Housing manufactured from

chemical resistant Valox®

IP65, NEMA 3R watertight,

and outdoor rated

Two photocells for daylight

harvesting

IP66, NEMA 4X,

outdoor rated

Photocell makes sure

lights stay off when there

is sufcient daylight

Isolated relay provides

signalling to HVAC and

ventalation systems

Stainless steel hardware

and settings access cover

HMHB21UPCW

AHP1600WRP

with HAP4

Valox ® is a trademark of SABIC Innovative Plastics, acquired from General Electric Company.

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

E-11 www.hubbell-wiring.com Wiring Device-Kellems

®

H-MOSS® Controls

H-MOSS®|MAXX™ Harsh Environment Occupancy Sensors

Ordering Information

Watertight OPTIMYZER®

IP65, NEMA 3R, outdoor rated, -40°F to 149°F (-40°C to 65°C) operating temperature range.

Description Voltage Catalog Number

Pir sensor, relay with photocell 120-347V AC HMHB21UPCW

Pir sensor, 2 relays with photocell 120-347V AC HMHB22UPCW

Pir sensor, 1 double pole relay with photocell 208, 240V AC HMHB23APCW

Pir sensor, 1 double pole relay with photocell 480V AC HMHB23BPCW

Pir sensor, with photocell 24V DC HMHB2LVPCW*

180° Lens HMHBL180

360° Lens (included) HMHBL360

Aisle lens HMHBLA

End of aisle lens HMHBLEA

Note: *For use with a CU series control unit: CU300HD (120/277V AC, 50/60 Hz), CU347A (347V AC, 60 Hz).

See pages E-21 for coverage patterns and technical specifications.

Outdoor Rated Watertight Wall Mount PIR Sensor

IP66, NEMA 4X, heavy duty wall or pendant mount sensor with -40°F to 149°F (-40°C to 65°C) operating

temperature range and 160° of coverage.

Description Voltage Catalog Number

PIR sensor, with isolated relay and photocell 24V DC AHP1600WRP

Adaptor plate for 1-gang FS boxes HAP1

Adaptor hub and nipple for Killark NJ series boxes HAP2

Adaptor plate for Killark NV series boxes HAP3

½" NPT threaded hub HAP4

Note: For use with a CU series control unit: CU300HD (120/277V AC, 50/60 Hz), CU347A (347V AC, 60 Hz).

See pages E-21 for coverage patterns and technical specifications.

Extreme Temperature PIR Ceiling Sensor

Upgraded ceiling sensor with -40°F to 149°F (-40°C to 65°C) operating temperature range.

Use ACIPE to make NEMA 4X watertight.

Description Voltage Catalog Number

PIR sensor, with isolated relay and photocell 24V DC AHP1500CRP

IP66, NEMA 4X enclosure ACIPE

Note: For use with a CU series control unit: CU300HD (120/277V AC, 50/60 Hz), CU347A (347V AC, 60 Hz).

See pages E-21 for coverage patterns and technical specifications.

Heavy Duty Control Unit

Robust latching relay provides reliable performance over many different applications, including plug

loads. 20A 100-277V AC, 1HP @ 120V, 2HP @ 240/277V. Auto or Manual-On operation. Powers up to

six low voltage sensors.

Description Voltage Catalog Number

Heavy duty control unit 120-277V AC CU300HD

Note: See page E-25 for technical specifications. CU300HD

AHP1600WRP

ACIPE with

AHP1500CRP

HMHB21UPCW

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

www.hubbell-wiring.com E-12 Wiring Device-Kellems

®

Three operation modes available:

Auto-On, Auto-On Low-Light

and Manual-On

Passive infrared motion detection

with advanced digital signal

processing for ne motion

detection

Auto-On Low-Light feature will

only turn lights on automatically

if there is less than approximately

10 Lux (1 fc) of ambient light

10-year battery life design

8A lighting, 3A fan

load capacity

Green LED provides

operation and setup

feedback

No neutral required,

no leakage to ground

LED and CFL compatible

with supplied load adaptor

Digital push button

operation provides user

control

Service switch prevents

lights from coming on

during re-lamping

Lens illuminates during

test mode to verify

coverage

Adjustments available

for Timeout, Activity,

and Auto-On settings

Accessible test buttons

make setup easy

WLS1278W

with NP26W

H-MOSS® Controls

WL-Series Wireless Sensors and Controls

Features and Benefits

WLP450C

Clear Connect is a registered trademark of Lutron Electronics Co., Inc.

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

E-13 www.hubbell-wiring.com Wiring Device-Kellems

®

H-MOSS® Controls

WL-Series Wireless Sensors and Controls

Featuring Passive Infrared Technology

Clear Connect is a registered trademark of Lutron Electronics Co., Inc.

Wireless

Daylight Sensor

Wireless Wall

Mount Sensor

Wireless

Wall Switches

Wireless Ceiling and Wall

Mount Sensors

Hubbell's WL-Series Wireless Sensors and Controls are the ideal solution for renovation projects aimed at reducing energy

consumption. These sensors use DSP Enhanced passive infrared technology to detect movement of heat from people to turn

lights on when a room is occupied and off when vacant. The sensors wirelessly transmit Clear Connect commands to the

associated control devices, reducing the need for additional wiring for ease and speed of installation and energy savings.

Eliminates need to run extra wires

Supports highly recongured spaces

Complete projects quickly

Helps manage energy consumption

Wireless Ceiling Mount Sensor

Description Color Catalog Number

Ceiling mount 360° / 324-676 ft2 White WLP450C

Wireless Wall Mount Sensor

• Detection at longer distances is best when motion occurs at right angles to the sensor

• Multiple sensors can be used to extend coverage

• Mount Hallway Sensor at the end of a hallway with a clear view down the length of a hall

Description

Wall mount

180° / 3000 ft2

Corner mount

90° / 2500 ft2

Hallway

up to 150 linear ft

Color White White White

Catalog Number WLP3000W WLP2500W WLP150H

Compatible Controls: WSL1278xx switch, WLC316R control unit, or any Lutron Clear Connect enabled control device.

Wireless Daylight Sensor

Description Color Catalog Number

Daylight sensor 0107,000 Lux (0-10,000 fc) White WLDH

Compatible Controls: WSL1278xx switch, WLC316R control unit, or any Lutron Clear Connect enabled control device.

Note: See pages E-22 to E-24 for coverage patterns and technical specifications.

Wireless Wall Switches

Description Color Catalog Number

8A Lighting, 3A Fan (1/10 HP motor, 120V only), Spec Grade

Electronic Switch 120277V. No neutral wire required

Ivory

White

WLS1278I

WLS1278W

Accessory Switch 120V Ivory

White

WLAS120I

WLAS120W

Accessory Switch 277V Ivory

White

WLAS277I

WLAS277W

Compatible Transmitters: WLP series and WLDH sensors any Lutron Clear Connect enabled sensor.

Wireless Control Unit

Description Catalog Number

Wireless load control unit with isolated relay, 16A, 120V or 277V AC WLC316R

Compatible Transmitters: WLP series and WLDH sensors any Lutron Clear Connect enabled sensor.

WLP450C

WLP150H

WLS1278I WLAS277W

WLC316R

WLDH

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

www.hubbell-wiring.com E-14 Wiring Device-Kellems

®

H-MOSS® Controls

Plug Load Control Products for ASHRAE and CEC Title 24 Compliance

System Overview / Methods for Complaince

ASHRAE 90.1-2010 mandates that 50% of all outlets in private ofces, open ofces, and

computer classrooms must be automatically controlled by occupancy or time based schedules.

This also includes outlets in modular furniture. Hubbell provides solutions for compliance that are

cost effective and installer friendly. Bellow are two examples. Additional examples and design

resources are located at www.hubbell-wiring.com/energy.aspx

Wired

Utilizing low voltage wiring provides installers with a familiar method of wiring and installation.

Specify CU300HD to control outlets and use AAR or CU300A to control the lighting. Utilize

alternating outlet or split receptacle wiring as required to control at least 50% of the outlets

in the space.

Wireless

Wireless communication takes complexity out of retrot and difcult installations by eliminating low

voltage wires running between lighting and receptacle control units. This gives installers exibility

to quickly deploy, add additional devices, and congure and re-congure the system as needed.

Hubbell's WL series controls utilize Lutron's proven Clear Connect communication and are

compatible with other Clear Connect devices, such as Hubbell's wireless occupancy sensors.

CU300xx

CU300HD

Controlling 50%

of Outlets

X

Not used

WLCU301

WLC301

Controlling 50%

of Outlets

DR20LA

Shown with adhesive label

to denote the device is being

automatically controlled.

Labels provided with each

plug load control unit.

Clear Connect is a registered trademark of Lutron Electronics Co., Inc.

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

E-15 www.hubbell-wiring.com Wiring Device-Kellems

®

H-MOSS® Controls

Plug Load Control Products for ASHRAE and CEC Title 24 Compliance

Control Units

Hubbell Plug Load Control Products

• Wired or wireless exibility

• UL/cUL 916 listed for energy management equipment

• Listed for 20A enclosed switching

• Heavy duty 60A rated mechanical latching relay;

silver alloy contacts

• Zero cross switching

• Expanded operating temperature range

• 24V DC, 250mA DC power output on applicable units

• Low voltage output short circuit protection

• UL2043 plenum rated except WLC402

• Controlled outlet labels provided with control units

Heavy Duty Control Unit

Robust latching relay provides reliable performance over many different applications, including plug

loads. 20A 100-277V AC, 1HP @ 120V, 2HP @ 240/277V. Auto or manual-on operation. Power up to

six low voltage sensors.

Description Voltage Catalog Number

Heavy duty control unit 100-277V AC CU300HD

Note: See page E-25 for technical specifications.

Heavy Duty Control Unit with Wireless Transmit

CU300HD with functionality of WLCA integrated to wirelessly activate additional load control units.

Takes the place of CU300A's normally used to control just lighting. 20A 100-277V AC, 1HP @ 120V,

2HP @ 240/277V. Auto or manual-on operation. Power up to six low voltage sensors.

Description Voltage Catalog Number

Heavy duty control unit with Clear Connect 100-277V AC WLCU301

Wireless Status Transmitter

Low voltage powered unit transmits occupancy or timer status to associated load control receivers.

Use with CU300xx and low voltage sensors/timers to upgrade existing lighting control systems to

support plug load control.

Description Voltage Catalog Number

Wireless transmitter with Clear Connect, for use with CU300xx 24V DC WLCA

Heavy Duty Load Control Units with Wireless Receive

These units receive wireless Clear Connect commands to turn on and off power to downstream loads.

Utilize these control units to wirelessly switch a circuit of receptacles or any other applicable load.

20A 100-277V AC, 1HP @ 120V, 2HP @ 240/277V.

Description Voltage Catalog Number

1 - Circuit heavy duty control unit with Clear Connect 100-277V AC WLC301

2 - Circuit heavy duty control unit with Clear Connect 100-277V AC WLC302

Furniture Feed Box with Heavy Duty Relays and Wireless Receive

Furniture feed box receives wireless Clear Connect commands and controls 2-circuits in furniture

electrical feeds. It supports wall mounting to existing 1 or 2-gang junction boxes. Additionally, the box

can be secured to the furniture or on the floor. 20A 100-277V AC, 1HP @ 120V, 2HP @ 240/277V.

Description Voltage Catalog Number

2 - Circuit heavy duty furniture freed box with

Clear Connect

100-277V AC WLC402W

Note: See page E-26 for technical specifications.

WLCU301

WLC301

CU300HD

WLCA

WLC402W

Clear Connect is a registered trademark of Lutron Electronics Co., Inc.

Wired

Wireless

Operates in a "quiet" 434MHz FCC band. Communication range: 30 ft obstructed or 60 ft

line of sight

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

www.hubbell-wiring.com E-16 Wiring Device-Kellems

®

Load 1

Red

Black

120/277V AC

Green

Ground

Red

Violet

Black

Blue

Line circuit

120/277V AC

Green

Ground

Load 1

Load 2

Red

Violet

Black

Blue

Line circuit 1

120/277V AC

Line circuit 2

120/277V AC

Green

Ground

Load 1

Load 2

Neutral

Hot

Ground

Black Red

Green

Neutral

Hot

Ground

Black

Red

Green

Violet

Blue

Lighting

Load A Lighting

Load A

Lighting

Load B

Wiring Schematic AD, AU, AP, 1277/2000 Series Wall Switch Sensors

H-MOSS® Controls

Specifications and Wiring Schematics

Dual Technology and Ultrasonic Wall Switches

Adaptive Dual Technology Wall Switches

AD2000 Series

Electrical

Power Supply 120/277V AC, 50/60Hz

Load Capacity

Incandescent 0 to 800 watts

120V AC Ballast 0 to 1000 watts

277V AC Ballast 0 to 1800 watts

Agency Approvals cULus Listed

Physical

Housing High impact plastic (UL-94-5V)

Lens Dual element pyrometer and 12 element

cylindrical hard lens

Dimensions Face 2.59"H x 1.73"W, 0.37"D (from wall out)

Mounting Height 42 to 54 inches above floor

Environmental

Operating 32°F to 104°F (0°C to 40°C);

0% to 95% non-condensing relative humidity

Controls

Time Delay Digital, adaptive 4 to 30 minutes

Ambient Light Adjustable ambient light override, 10 to 500

foot candles

Front Press Switch Auto/Off

Sensitivity Adaptive 0% to 100%

Service Switch Air gap off

Sensing Indicator

Passive Infrared Red LED

Ultrasonic Green LED

Adaptive Technology Ultrasonic and PIR Wall Switches

AP2000 and AU2000 Series

Electrical

Power Supply 120/277V AC, 50/60Hz

Load Capacity

Incandescent 0 to 800 watts

120V AC Ballast 0 to 1000 watts

277V AC Ballast 0 to 1800 watts

Agency Approvals cULus Listed

Physical

Housing High impact plastic (UL-94-5V)

Lens Dual element pyrometer and 12 element

cylindrical hard lens (AP2000 only)

Dimensions Face 2.59"H x 1.73"W, 0.37"D (from wall out)

Mounting Height 42 to 54 inches above floor

Environmental

Operating 32° F to 104°F (0°C to 40°C);

0% to 95% non-condensing relative humidity

Controls

Time Delay Digital, adaptive 4 to 30 minutes

20 minutes default

Ambient Light Adjustable ambient light override, 10 to 500

foot candles

Front Press Switch Auto/Off

Sensitivity Adaptive 0% to 100%

Service Switch Air gap off

Sensing Indicator

Passive Infrared Red LED (AP series only)

Ultrasonic Green LED (AU series only)

Single Circuit Wiring Dual Circuit Sensor, Wired for Dual Circuits Dual Circuit Sensor, Wired for Single Circuit

Single Circuit Sensors, Wired as 3-Way Sensors* Dual Circuit Sensors, Wired as 3-Way Sensors*

Note: *Load can not exceed the rating of one switch.

Sensor is shipped with all dip switches in the OFF position (factory default).

For step dimming,

bi-level, and dual

ballasted xtures

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

E-17 www.hubbell-wiring.com Wiring Device-Kellems

®

Wall Switches Coverage Patterns

Major Motion: UltrasonicUltrasonic PIRPIR

Minor Motion:

AD2000 Series

28'

28'

24'

29'

26'

21'

50'

AP2000 Series

28'

28'

50'

AU2000 Series

14.5'

14.5'

24'

26'

21'

16'

16'

40'

AT1277 Series

3.5º

3.5º

10'

(3.0m)

Mounting Height

42" to 54"

(106.7 to 137.2cm)

20'

(6.1m)

See Horizontal

View for Range

14.5"

(36.8cm)

29"

(73.3cm)

Vertical Coverage

AT1277 Series

Wall Switches Coverage Patterns

Major Motion: PIRPIR

Minor Motion:

H-MOSS® Controls

Coverage Patterns

ATP2000, WS2000 Series

12'

16'

12'

16'

40'

20'

Mounting Height

48" (121.9 cm)

20' (6.1m)

40' (12.2m)

Vertical Coverage

ATP2000, WS2000 Series

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

www.hubbell-wiring.com E-18 Wiring Device-Kellems

®

Adaptive Technology PIR Wall Switches

AT1277 Series

Electrical AT1277 Series

Power Supply 120/277V AC, 50/60Hz

Load Capacity

120V AC 0 to 1800 watts

277V AC 0 to 4155 watts

Agency Approvals UL Listed, cULus Certified

Physical

Housing Flame retardant UL 94 V-0 ABS

Lens Polyethylene

Dimensions Face 2.61"H x 1.29"W, 0.73"D (from wall out)

Mounting Height 42 to 54 inches above floor

Environmental

Operating 32°F to 122°F (0°C to 50°C) with rate of

change not exceeding 20°F

(11°C) per hour; 20% to 90% non-condensing

relative humidity

Storage -20°F to 150°F (-29°C to 65°C);

20% to 90% non condensing relative humidity

Controls

Time Delay Digital, test (15 seconds),

Adaptive 5 to 30 minutes

Ambient Light Digital, pushbutton, 30 to 300 foot candles

Front Press Switch Auto/Momentary Off (30 minutes after last

motion, switch returns to automatic mode)

Service Switch Auto/Off

Sensing Indicators

Passive Infrared 2-color LED (red, green)

Note: *Load can not exceed the rating of one switch.

H-MOSS® Controls

Specifications and Wiring Schematics

Passive Infrared Wall Switches

Hot

Hot

Ground

Ground

Green

Green Green

Yellow

Neutral Neutral

Red

Normal Wiring

Sensors Wired as

3-Way Sensors*

(ATP/WS2000 Only)

White (Neutral Versions Only)

Black White

Black

Red Red

Yellow

White (Neutral

Version Only) Load Load

ATP/WS2000

Only

Adaptive Technology PIR Wall Switches

ATP2000, WS2000 and WS1000 Series

Electrical ATP/WS2000 Series WS1000 Series

Power Supply 120/277V AC, 60Hz 120V AC, 60Hz

Load Capacity

Incandescent 0 to 1000 watts 0 to 500 watts

120V Ballast 0 to 1000 watts 0 to 500 watts

277V Ballast 0 to 1800 watts N/A

Agency Approvals

Warranty

cULus Listed

5 years

cULus Listed

5 years

Physical ATP/WS2000 and WS1000 Series

Housing Flame retardant UL 94 V-0 ABS

Lens Polyethylene

Dimensions Face 2.59"H x 1.30"W, 0.61"D (from wall out)

Mounting Height 42 to 54 inches above floor

Environmental ATP/WS2000 and WS1000 Series

Operating 32°F to 122°F (0°C to 50°C) with rate of change

not exceeding 20°F (11°C) per hour; 20% to 90%

non-condensing relative humidity

Storage -40°F to 150°F (-40°C to 65°C);

20% to 90% non condensing relative humidity

Controls ATP/WS2000 Series WS1000 Series

Time Delay ATP: Auto

WS: Manual 20 seconds

to 30 minutes

Manual 20 seconds to

30 minutes

Ambient Light Digital, pushbutton,

10 to 500 foot candles

n/a

Front Press Switch On/Off On/Off

Service Switch Off (service)

Vac (manual-on)

Occ (auto-on)

Off (service)

On (normal operation)

Sensing Indicator ATP/WS2000 and WS1000 Series

Passive Infrared Red LED

Wiring Schematic ATP2000 and WS2000 Series Wall Switches

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

E-19 www.hubbell-wiring.com Wiring Device-Kellems

®

32'

64'

45'

23'

23'

32'

32'

23'

ATU2000C Series ATU1000C Series

26'

18'

14'

20'

ATU500C Series

64'

16'

ATU2000C Series

Hallway Application

ATD2000C Series ATD1000C Series ATD500C Series ATP1500C Series ATP600C Series

22'

26' 18'

12'

14'

20'

22'

64'

45'

12'

23'

32'

22'

32'

23'

12'

23'

32'

22' 12'

11'

7'

Ceiling Sensors Coverage Patterns

Major Motion: UltrasonicUltrasonic PIRPIR

Minor Motion:

LVPR1500R(P)

20'

Wall Mount Sensors Coverage Patterns

20

10

0

30

120'

7'

7'

120'

ATP120HB Series

Top View

Side View

40'

20'

32'

23'

32'

23'

ATD1600W Series

40'

20'

ATP1600W Series

Major Motion: UltrasonicUltrasonic PIRPIR

Minor Motion:

H-MOSS® Controls

Coverage Patterns

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

www.hubbell-wiring.com E-20 Wiring Device-Kellems

®

H-MOSS® Controls

Specifications

Ceiling and Wall Mount Sensors

Adaptive Dual Technology, Ultrasonic and Passive Infrared Ceiling and Wall Mount Sensors

ATD, ATU, and ATP Series

Electrical

Power Requirements 24V DC nominal, 33mA from Hubbell CU series control unit

Isolated Relay Normally open and normally closed

(sensors with RP suffix) Terminals available

Agency Approvals UL Listed

Physical Ceiling Sensors

Housing Flame retardant UL 94 V-0 ABS

Lens Polyethylene

Dimensions 1.5"H x 4.5"D

Color Office white

Mounting Height 8 to 12 feet

Physical Wall Mount Sensors

Housing Flame retardant UL 94 V-0 ABS

Lens Polyethylene

Dimensions 6"H x 2"W x 1.5"D

Color Office white

Mounting Height 8 to 12 feet, 8 to 30 feet (ATP120HB series)

Environmental

Operating 32°F to 104°F (0°C to 40°C) with rate of change not exceeding 20°F (11°C) per hour;

0% to 95% non condensing relative humidity

Storage -20°F to 150°F (-29°C to 65°C); 0% to 95% non-condensing relative humidity

Controls

Time Delay Test (8 seconds), adaptive 8 to 40 minutes

Ambient Light 1 to 1000 foot candles

Sensitivity Adaptive 0 to 100%

Sensing Indicators

Ultrasonic (ATD and ATU Series) Green LED

Passive Infrared (ATD and ATP Series) Red LED

OPTIMYZER® High Bay

HMHB Series

User Interface 2 four-pin dip switches (standard version)

3 four-pin dip switches (photosensor version)

Timer time-outs Primary: 8-second test mode – 4, 8, 16 and 30 minute time-outs

Secondary: Can be disabled – 30, 60 and 90 minute time-outs

Passive infrared Dual element pyrometer and spherical Fresnel lens

Photosensor Range

(Photosensor version only)

50 to 3000 foot candles, set point adjustable

Coverage 360° (includes masking kit for aisle and end-of-aisle applications).

Lens: Below 30 ft: 1.4 – 42 ft radius; mounted @ 30 ft; up to 45 ft: 1.1 -

49.5 ft radius; mounted @ 45 ft

Load ratings

(line voltage units)

120V AC: 0 to 800

watts watts

277V AC: 0 to 1200 watts ballast

347V AC: 0 to 1500 watts ballast

208/240V AC: 0 to 1200 watts ballast

480V AC: 0 to 2400 watts ballast

¼-HP motor load @ 120V AC,

1/6 HP @ 347V

Operating environment

(

Indoor use only)

Operating temperature: (standard version) 32°F to 149°F (0°C to 65°C);

Relative humidity (non-condensing): 0% to 95%

Construction Casing: High-impact injection-molded thermoplastic

Size and weight Size: 4.4 inch x 3.6 inch x 2.0 inch; Weight: 7 oz.

Color White

Mounting Mounts directly to the end of a xture through an extended ½ inch chase

nipple. For deeper body xtures, an optional Extender Adapter (available

separately) positions the sensor ush or below the bottom of the reector

for a full eld of view

Certications cULus Listed

R

1

H

= 0' to 30'

R

2

R

1

= 1.4 x H

R

2

= 1.1 x H

H

= 30' to 45'

Coverage Pattern

Major Motion: PIRPIR

Minor Motion:

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

E-21 www.hubbell-wiring.com Wiring Device-Kellems

®

R

1

H

= 0' to 30'

R

2

R

1

= 1.4 x H

R

2

= 1.1 x H

H

= 30' to 45'

Coverage Pattern

Major Motion: PIRPIR

Minor Motion:

H-MOSS® Controls

Specifications

Ceiling and Wall Mount Sensors

Harsh Environment Passive Infrared Ceiling and Wall Mount Sensors

AHP Series

Electrical

Power Requirements 24V DC nominal, 33mA from Hubbell CU series control unit

Isolated Relay Normally open and normally closed

(sensors with RP suffix) Terminals available

Agency Approvals cULus Listed

Physical Ceiling Sensor

Housing Flame retardant UL 94 V-0 ABS

Protection NEMA 4X, when used with ACIPE

Lens Polyethylene

Dimensions 1.5"H x 4.5"D

Color Office white

Mounting Height 8 to 12 feet

Physical Wall Mount Sensor

Housing Flame retardant UL 94 V-0 Valox®

Protection NEMA 4X, IP66, outdoor use rated

Lens Polyethylene

Dimensions 6"H x 2"W x 1.5"D

Color Gray

Mounting Height 8 to 12 feet

Environmental

Operating -40°F to 149°F (-40°C to 65°C) with rate of change

not exceeding 20°F (11°C) per hour;

0% to 95% non condensing relative humidity

Controls

Time Delay Test (8 seconds), adaptive 8 to 40 minutes

Ambient Light 1 to 1000 foot candles

Sensitivity Adaptive 0 to 100%

Sensing Indicators

Passive Infrared Red LED

HMHBxxUPCW Series

User Interface 2 four-pin dip switches (standard version)

3 four-pin dip switches (photosensor version)

Timer time-outs Primary: 8-second test mode 4, 8, 16 and 30 minute time-outs

Secondary: Can be disabled 30, 60 and 90 minute time-outs

Passive infrared Dual element pyrometer and spherical Fresnel lens

Photosensor Range

(Photosensor version only)

50 to 3000 foot candles, set point adjustable

Coverage 360° (includes masking kit for aisle and end-of-aisle applications)

Lens: Below 30 ft: 1.4 – 42 ft radius; mounted @ 30 ft.; Up to 45 ft.:

1.1 - 49.5 ft. radius; mounted @ 45 ft.

Load ratings

(line voltage units)

120V AC: 0 to 800 watts ballast or tungsten

277V AC: 0 to 1200 watts ballast

347V AC: 0 to 1500 watts ballast

208/240V AC: 0 to 1200 watts ballast

480V AC: 0 to 2400 watts ballast

¼-HP motor load @ 120V AC, 1/6 HP @ 347V

Operating environment

(Indoor use only)

Operating temperature: (standard version) 32°F to 149°F (0°C to

65°C); (low temperature version): -40°F to 149°F (-40°C to 65°C)

Relative humidity (non-condensing): 0% to 95%

Construction Casing: High-impact injection-molded thermoplastic

Size and weight Size: 4.4 inch x 3.6 inch x 2.0 inch; Weight: 7 oz.

Color White

Mounting Mounts directly to the end of a xture through an extended ½ inch

chase nipple. For deeper body xtures, an optional Extender

Adapter (available separately) positions the sensor ush or below

the bottom of the reector for a full eld of view

Certications ETL, Conforms to UL STD 916, Certied to CAN/USA STD 22.2

No. 61010-1-04 and Title 24 Certied

Warranty 5 year limited

AHP1500CRP

22'

26' 18'

12'

14'

20'

22'

64'

45'

12'

23'

32'

22'

32'

23'

12'

23'

32'

22' 12'

40'

20'

AHP1600WRP

Coverage Pattern

Major Motion: PIRPIR

Minor Motion:

Valox ® is a trademark of SABIC Innovative Plastics, acquired from General Electric Company.

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

www.hubbell-wiring.com E-22 Wiring Device-Kellems

®

Wireless Ceiling Mount Sensor Coverage Patterns

Sensor Coverage Chart (for sensor mounted in center of room)

Ceiling height Maximum room dimensions for complete oor coverage*

8 ft (2.4 m) 18 ft x 18 ft (5.5 m × 5.5 m) 324 ft 2 (30.2 m 2)

9 ft (2.7 m) 20 ft x 20 ft (6.1 m × 6.1 m) 400 ft 2 ( 37. 2 m 2 )

10 ft (3.0 m) 22 ft x 22 ft (6.7 m × 6.7 m) 484 ft 2 (44.9 m 2 )

12 ft (3.7 m) 26 ft x 26 ft (7.9 m × 7.9 m 676 ft 2 (62.4 m 2 )

Note: * 12 ft (3.7 m) is the recommended maximum mounting height

11'

7'

8'

6'

12'

Wireless Wall Mount Sensor Coverage Patterns Corner Mount Coverage Patterns

H-MOSS® Controls

Coverage Patterns

WL-Series Wireless Sensors

Note: *Sensor mounting shown at 7 ft (2.1 m). Mounting height should be between 6 and 8 ft (1.6 and 2.4 m).

Side View

WLP450C

60'

50'

25'

18'

25'

18'

0'

0

750'

60'

Side View

Top View

WLP3000W

0

7

35'

50'

Side View

35'

50'

Top View

WLP2500W

Clear Connect is a registered trademark of Lutron Electronics Co., Inc.

Top View

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

E-23 www.hubbell-wiring.com Wiring Device-Kellems

®

Specications

Electrical Operating voltage: 3V

Operating current: 14 μA nominal

10-year battery life design

Supplied with one CR 123 lithium battery

Non-volatile memory (saved changes are stored during power loss)

Construction High impact, UL 94-5V plastic

Operating Environment Indoor use only

Operating temperature: 32˚F to 104˚F (0˚C to 40˚C)

Range RF range is 30 ft (10m) obstructed, 60 ft (18m) line of sight

Sensor Coverage Test Dedicated test button

Lens illuminates orange in response to motion during test mode

Wireless Communication Test Dedicated test button; Turn associated loads on and off

Time Out Options 1 minute (intended for use in high-activity, briey occupied areas only); 5 minutes;

15 minutes (default setting); 30 minutes

Auto-On Options "Enabled" – Sensor turns lights ON and OFF automatically – default setting

"Disabled" – Lights must be turned ON manually from a switching device

Sensor turns lights OFF automatically

Sensitivity Options Low Activity (default setting); Medium Activity; High Activity

Certications cULus Listed, FCC Certied, IC Certied

Meets CA (USA) Energy Commission Title 24 requirements

Warranty 1 year

Wireless Hallway Sensor Coverage Patterns

10'

150'

7'

150'

0

Side View

Top View

Sensor Coverage Chart (Hallway)

Width of Hall Length of Hall

6 ft (1.0 m) or less 50 ft (15.2 m)

8 ft (2.4 m) 100 ft (30.5 m)

10 ft (3.0 m) or more 150 ft (45.7 m)

Note: *Sensor mounting shown at 7 ft (2.1 m). Mounting height

should be between 6 and 8 ft (1.6 and 2.4 m).

H-MOSS® Controls

Coverage Patterns

WL-Series Wireless Sensors

WPL150H

Clear Connect is a registered trademark of Lutron Electronics Co., Inc.

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

www.hubbell-wiring.com E-24 Wiring Device-Kellems

®

H-MOSS® Controls

Specifications and Wiring Schematics

WL-Series Wireless Load Controls

Wireless Control Unit (WLC316R)

Electrical Operating voltage: 120/277V, 50/60Hz

LED status indicator: displays load status and provides programming feedback

Power failure memory: (Relay returns to previous level prior to interruption)

Output is non-latching

Operating

Environment

Indoor use only

Ambient operating temperature: 32°F to 131°F (0°C to 55°C);

Relative humidity: 0% to 90% humidity, non-condensing

Load Maximum load: 16A general purpose. No minimum

Motor rating: 0.5 HP (120V AC), 1.5 HP (277V AC)

Isolated Relay Normally open (NO) and normally closed (NC) dry contacts

Maintained latching output

The isolated relay is not rated to control unclamped, inductive loads.

Inductive loads include, but are not limited to relays, solenoids and motors.

To control these types of equipment

Range RF range is 30 ft (10m) obstructed, 60 ft (18m) line of sight

Certications UL Listed, UL 2043 Plenum Rated, FCC Approved. Complies with the limits

for a Class B device, pursuant to Part 15 of the FCC rules. CSA and IC

Warranty 1 year

Range Diagram

40 ft (12 m)

Install in center of room to

maximize RF coverage.

Wireless Transmitter

must be installed within

30 ft (10 m) of the

load control unit.

Line of sight distance

60 ft (18 m)

Wireless

Occupancy

Sensor

30 ft (10 m)

Maximum

30 ft (10 m)

Contact Hubbell first for applications using foil-backed or metallic ceiling tiles.

Contact Hubbell rst for applications

using foil-backed or metallic ceiling tiles.

Wireless Wall Switch (WLS1278 Series)

Electrical Operating voltage: 120/277V, 50/60Hz

Green indicator light

Operating

Environment

Indoor use only

Ambient operating temperature: 32°F to 104°F (0°C to 40°C),

Relative humidity: 0% to 90% humidity, non-condensing

Wire Size #20 to 16 AWG (0.5 to 1.5mm 2 ) solid or stranded wire

Capacity Up to 9 WLAS accessory switches can be congured to work together with one WLS1278

Range RF range is 30 ft (10m) obstructed, 60 ft (18m) line of sight

Certications UL Listed, CSA Certied, FCC Approved

Complies with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules

Warranty 1 year

Wiring Diagram - Wireless Wall Switch (WLS1278 Series)

Note: *The included LUT-MLC ensures proper function when flfluorescent, CFL,

or LED loads are used. Install the LUT-MLC inside a load fixture or in a

separate J-box of the circuit.

1 When using controls in single location installations, tighten the blue

terminal without any wires attached. DO NOT connect the blue terminal to

any other wiring or to ground.

2 Up to 9 Accessory Switches may be connected to the Wireless Switch.

Total blue terminal wire length may be up to 250 ft (76m).

3 Requires WLAS120 for 120V applications, and WLAS277 for 277V

applications.

Single Location Installation

WLS1278xx*

Brass

Black

Blue - unused, tighten1

Optional

Green

Ground

Hot/Live

Neutral

Switch

Load

120V

50/60 Hz

or

277V

50/60 Hz

LUT-MLC*

WLS1278xx

Switch

Multi-Location Installation2

with WLAS1278xx or WLAS277xx3

Brass

Black

Blue

Green

Ground

Brass

Black

Blue

Green

Ground

Brass

Black

Blue

Green

Ground

Hot/Live

Neutral

WLAS Series

Companion Switch WLAS Series

Companion Switch

Load

120V

50/60 Hz

or

277V

50/60 Hz

Optional

LUT-MLC*

Clear Connect is a registered trademark of Lutron Electronics Co., Inc.

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

E-25 www.hubbell-wiring.com Wiring Device-Kellems

®

Control Units - CU300/347A Series

Electrical CU300A(M) CU347A CU300HD

Power Supply 120-277V AC, 50/60Hz 347V AC, 60Hz 100-277V AC, 50/60 Hz

Power Output 24V DC, 150mA 24V DC, 100mA 24V DC 250mA

Load Capacity

Incandescent 0 to 1800 watts NA 100-277V, 20A Enclosed Switching

120V Ballast 0 to 2400 watts NA Motor Loads:

230V Ballast NA NA 1HP @ 120V

277V Ballast 0 to 5540 watts NA 2HP @ 240/277V

347V Ballast NA 0 to 5205 watts

AT Sensor/AAR Capacity 1 to 4 combined 1 to 3 combined 1 to 6 combined

Agency Approvals UL Listed, cULus Certified UL Listed, cULus Certified UL Listed, cULus

Physical

Housing Flame retardant UL 94-5VA thermoplastic Flame retardant UL 94-5VA thermoplastic

Dimensions 3.69"L x 2.33"W x 1.36"H 4.00"L x 3.4"W x 1.73"H

Color Black Black

Environmental

Operating 32°F to 104°F (0°C to 40°C); 0% to 90% non condensing relative humidity See CU300HD data sheet for ratings

Storage -20°F to 150°F (-29°C to 65°C); 0% to 90% non condensing relative humidity

Add-A-Relay - AAR

Electrical

Power Input 24V DC nominal, 33mA from Hubbell CU series control unit

Load Capacity

Incandescent 0 to 1800 watts

120V Ballast 0 to 2400 watts

230V Ballast 0 to 3680 watts

277V Ballast 0 to 5540 watts

347V Ballast 0 to 5205 watts

Agency Approvals UL Listed

Physical

Housing Flame retardant UL 94-5V thermoplastic

Dimensions 3.69"L x 2.33"W x 1.36"H

Color Black

Environmental

Operating 32°F to 104°F (0°C to 40°C); 0% to 90% non condensing relative humidity

Storage -20°F to 150°F (-29°C to 65°C); 0% to 90% non condensing relative humidity

H-MOSS® Controls

Specifications

Control Units and Add-A-Relay

CU300xx

CU300HD

Controlling 50%

of Outlets

X

Not used

Wired Lighting and Plug Load Control

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

www.hubbell-wiring.com E-26 Wiring Device-Kellems

®

H-MOSS® Controls

Specifications and Wiring Schematics

Passive Infrared Wall Switches

WLC Load Control with Wireless Clear Connect Communication

Electrical WLCA WLCU301 WLC301 WLC302 WLC402W

Power Supply 24V DC 100-277V AC, 50/60Hz 100-277V AC, 50/60Hz 100-277V AC, 50/60Hz 100-277V AC, 50/60Hz

Power Output N/A 24V DC 250mA N/A N/A N/A

Circuits Controlled N/A 1122

Load Capacity 100-277V, 20A

1HP @ 120V AC

2HP @ 240/277V

100-277V, 20A

1HP @ 120V AC

2HP @ 240/277V

100-277V, 20A

1HP @ 120V AC

2HP @ 240/277V

100-277V, 20A

1HP @ 120V AC

2HP @ 240/277V

Agency Approvals UL Listed, cULus, FCC, IC

Device Type (Transmit

or Receive)

TX TX RX RX RX

Range (Standard/

Obtructed)

30 ft (10m) 30 ft (10m) 30 ft (10m) 30 ft (10m) 30 ft (10m)

Range (Unobstructed,

line of site)

60 ft (30m) 60 ft (30m) 60 ft (30m) 60 ft (30m) 60 ft (30m)

Physical

Housing Flame retardant UL 94-5VA thermoplastic

Dimensions 4.00"L x 3.4"W x 1.73"H 4.68"L x 4.94"W x 2.78"H

Color Black Black Black Black White

WLCU301

WLC301

Controlling 50%

of Outlets

CU300xx WLCA

WLC301

Controlling 50%

of Outlets

Easily upgrade existing occupancy based lighting control systems to support

automated plug load controls.

Wireless Lighting and Plug Load Control

Use WLC302

or 402 for dual

circuit control)

Clear Connect is a registered trademark of Lutron Electronics Co., Inc.

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

E-27 www.hubbell-wiring.com Wiring Device-Kellems

®

White

Black

Red

Red

Lighting Load

Red

Black

Blue

ATD, ATU and ATP Series Sensors**

Blue

Blk

Red

Blue

Blk

Red

Blue

Blk

Red

Switch*

*Optional Override Off Switch

White

Black

Red

Red

Lighting Load

NH

Red

Red

Lighting Load

NH

Red

Black

Blue

Red

Black

Blue

ATD, ATU and ATP Series Sensors**

Blue

Blk

Red

Blue

Blk

Red

AAR Add-A-Relay

White

Black

Red

Red

Lighting Load

Red

Red

Lighting Load

Red (+24V)

Black

Blue

Red (+24V)

Black

Blue

ATD, ATU and ATP Series Sensors**

Blue

Blk

Red

Blue

Blk

Red

Blue

Blk

Red

Blue

Blk

Red

White

White

Black

White

CU Series Control Unit

BlackBlue

CU Series Control Unit

ATD, ATU and ATP Series Sensors**

CU Series Control Unit

(Specify Voltage)

White

Black

Red

Red

Lighting Load

NH

NH

Lighting Load

Red (+24V)

Black

Blue

Red (+24V)

Black

Blue

Blue

Blk

Red

Blue

Blk

Red

Blue

Blk

Red

Blue

Blk

Red

White BlackBlue

White

Black

Red

Red

White

H-MOSS® Controls

Wiring Schematics

Ceiling and Wall Mount Sensors

Adaptive Dual Technology, Ultrasonic, and Passive Infrared Ceiling and Wall Mount Sensors

ATD, ATU and ATP Series

Two Circuit Application:

1 to 4 sensors wired to control unit and Add-A-Relay (control

unit switches circuit 1, Add-A-Relay switches circuit 2).

Note: **For wiring sensors with isolated relay and photocell option (models

with "RP" suffix): Photocell Option: Cap off Blue sensor wire. Connect

Gray sensor wire to Blue control unit wire. Isolated Relay Option:

Common-Blue/White wire, Normally Closed-Black/White wire,

Normally Open-Yellow/White wire.

Two Circuit Application:

Two control units wired in two circuits to operate 2 to 8 sensors

in a single zone. Maximum 4 sensors per control unit any

sensor will activate both lighting loads.

Single Circuit Application:

Two control units wired in parallel to operate 5 to 8 sensors

in a single zone. Maximum 4 sensors per control unit any

sensor will activate lighting.

Single Circuit Application:

1 to 4 sensors wired to control unit with optional override

off switch.

Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com

www.hubbell-wiring.com E-28 Wiring Device-Kellems

®

CU Series Control Unit

(Specify Voltage)

Red

Blk

Blue

Red

Blk

Blue

Red

Blk

Blue

Red

Black

Blue

Red

Red

Black

White White

Inboard Ballast

Outboard Ballast

ATD, ATU and ATP Series Sensors**

Single Pole Switch

Single Pole Switch

N

H

CU Series Control Unit

(Specify Voltage)

Red

Blk

Blue

Red

Blk

Blue

Red

Blk

Blue

Red

Black

Blue

Red

Red

Black

White White

ATD, ATU and ATP Series Sensors**

Traveler

3-Way Switch 3-Way Switch

Lighting Load

NH

CU Series Control Unit

(Specify Voltage)

Red

Blk

Blue

Red

Blk

Blue

Red

Blk

Blue

Red

Black

Blue

Red

Red

Black

White White

ATD, ATU and ATP Series Sensors**

Traveler

3-Way Switch 4-Way Switch

Lighting Load

3-Way Switch

Traveler

Lighting Contactor

ATD, ATU, ATP, PIR Series Sensors*

White

Black

Red

Red

Red (+24V)

Black

Blue

Blue

Blk

Red

Blue

Blk

Red

White

C

Multipole, Normally Open

Lighting contactor to be

H-MOSS® Controls

Wiring Schematics

Ceiling and Wall Mount Sensors

Adaptive Technology Dual, Ultrasonic, and Passive Infrared Ceiling and Wall Mount Sensors

ATD, ATU and ATP Series

Single Circuit, Dual Level Switching Application:

1 to 4 sensors wired to control unit with optional override

off switches.

Single Circuit, 4-Way Switching Application:

1 to 4 sensors wired to control unit with optional override

off switches.

Single Circuit, 3-Way Switching Application:

1 to 4 sensors wired to control unit with optional override

off switches.

Multi-Circuit Application:

1 to 4 sensors wired to control unit that is wired to a

multi-pole lighting contactor.

Note: **For wiring sensors with isolated relay and photocell option (models

with "RP" suffix): Photocell Option: Cap off Blue sensor wire. Connect

Gray sensor wire to Blue control unit wire. Isolated Relay Option:

Common-Blue/White wire, Normally Closed-Black/White wire,

Normally Open-Yellow/White wire.